# How Should Buyers Select A Dust-Resistant Protective Case?

> A buyer&#x27;s five-step method for selecting a dust-resistant protective case: read the closure statement, check rim stiffness, size the interior, verify the sample.

Human-readable page: https://kexincases.com/knowledge-center/how-should-buyers-select-a-dustresistant-protective-case/
Site overview for AI agents: https://kexincases.com/llms.txt

## Page content

Select a dust-resistant protective case by working from the contamination to the closure, not from a marketing word backwards. The short method is five steps: describe the dust you are actually excluding; read the supplier's closure statement and the test status behind it; check the geometry that keeps that closure under compression, which means wall thickness, parting-line continuity and latch positions; size the interior so the lid is used properly and the foam does not become a dust reservoir; and decide in advance what you will verify on a first article and what you will pay a lab to measure. On our own catalogue that method is easy to apply: 124 of 155 models publish a compressible gasket in a continuous moulded channel, 31 publish that no sealed closure is offered, and all 155 record the dust and water fields as unmeasured, so the selection decision is a construction decision you can inspect, not a rating you have to trust.

Quick answer

### Key points

- Ask the supplier for a closure statement and a test status separately; a moulded gasket channel and a measured rating are two different documents.
- 124 of our 155 models publish a compressible gasket in a continuous moulded channel; the other 31 state that no sealed closure is offered.
- Rim stiffness is part of the seal: every gasketed shell in our range publishes 3.0 mm wall or more, while the unsealed group publishes 2.0 mm to 2.9 mm.
- Size from usable interior volume, not external footprint, so the lid closes fully and the foam does not hold the closure open.
- Foam is a dust surface: specify a closed-cell cut with no exposed edge at the parting line, and send a drawing, photograph or sample.
- Treat accredited testing against your exact model and configuration as a priced work package in the request for quotation, not as an included promise.
- Plan the buying route around real lead times: 45 days for first articles on an existing mould, 125 days and 3,000 per component for a new mould.

## Step one: describe the dust before you describe the case

Every selection decision after this point depends on what is actually in the air around the equipment, so write it down in the request for quotation. Gypsum and concrete dust are abrasive and they settle into sliding surfaces. Wood and paper dust are fibrous and wrap around hinges and latch mechanisms. Metal fines and carbon are conductive, which turns a storage problem into a board-level fault. Coastal and de-icing salt aerosol is corrosive and needs a different conversation about hardware than a quarry does. A grain store, a demolition site, a machine shop, a roadway survey crew and a film unit on location all need a case, and they do not need the same case.

Then describe the handling cycle rather than the environment, because that is what decides whether a good closure stays good. How often is the lid opened, and on which side of the boundary? Is the case carried, rolled, or stacked in a vehicle? Does it sit in direct sun in a closed trailer, or is it shelved in a depot? Is the equipment packed warm and closed cold? A case that is opened twice a day on a verge has a completely different dust budget from one that is opened monthly in a workshop, and the buyer who cannot answer that question will overbuy or underbuy with equal confidence.

## Step two: read the closure statement, then read the test status

Ask two questions in this order and refuse to let them be merged. First, what is the closure built from? In our published data the answer per model is explicit: 124 models record a compressible gasket in a continuous moulded channel and 31 record that none is offered on that shell. That is a construction fact you can verify on the part with your eye and a feeler gauge. Second, what has been tested? On our range the dust-resistance field and the waterproof field are recorded as unmeasured on all 155 models, and the protection-rating field carries a standing note that no ingress code is stated and that accredited testing is quoted per configuration.

The reason to insist on the split is that most purchasing disputes in this category come from a word doing two jobs. Dust resistant, dust proof and sealed are marketing adjectives, and they tell you nothing about whether anyone passed air through the part. A closure statement tells you what exists; a test report tells you what was proven. If your programme requires a stated figure, buy the test as a line item against the exact model and configuration you intend to order, and be clear about who holds the report and whether it covers production units or only the sample submitted.

For comparison shopping, this is also the fastest way to separate factories from resellers. Ask for the wall thickness, the lid and base depth split, the narrow internal width and the latch positions on a specific model. A manufacturer answers with numbers from the tool; a trader answers with the same brochure text you already have. Our own model pages publish external and internal dimensions, wall thickness, net weight, internal volume and usable interior volume for this reason.

## Step three: check the geometry that keeps the closure under compression

A gasket only excludes dust while the rim it bears on stays flat, so rim stiffness belongs in the selection criteria rather than in the engineering afterthought. In our catalogue the correlation is visible in the published figures: all 124 gasketed models state a wall thickness of 3.0 mm or above, up to 6.0 mm on the largest shells, and the 24 unsealed models that publish a wall figure run between 2.0 mm and 2.9 mm. That is not a coincidence of positioning. A thin wall flexes under the latches and under stack load, and once the rim moves, the continuous channel becomes a series of short gaps.

Next look at the parting line as a physical path rather than as a circle on a drawing. The lid-to-base split tells you how much of the depth is above the seal and how much below, and that ratio decides whether a shallow instrument case or a deep-body case suits the kit. KX-1905 publishes a 25 mm lid over a 15 mm base with a 3.0 mm wall, which suits a flat instrument; KX-2813 publishes a 92 mm lid over a 25 mm base with a 2.8 mm wall and no gasket at all, which suits a taller kit stored indoors. Where the internal width narrows at the parting line, that published narrow dimension is the one your equipment has to clear, not the internal width at the floor.

Then count the latches and place them. Latch count is specified per configuration across all 155 models, which means it is yours to set, and the question a buyer should ask is simple: on this lid length, how many latch points are needed so compression in the middle of the long edge approaches the compression at the corners? A long-edge case closed by two corner latches will show a visible gap in the middle when you sight down it, and that gap is the dust path. Hinges, lock tabs and feet are fitted across the range; the latch plan is the part you specify.

## What to ask of each candidate group, side by side

| Selection Criterion | Gasketed Group (124 Models) | Unsealed Group (31 Models) | What The Buyer Should Ask For |
|---|---|---|---|
| Closure recorded per model | Compressible gasket in a continuous moulded channel, recorded as a measured construction feature | Model page states no sealed closure is offered on this shell | The closure statement on the quotation, not only the product title |
| Published wall thickness | 3.0 mm to 6.0 mm | 2.0 mm to 2.9 mm on the 24 models that publish a figure | Wall thickness at the rim, and the lid and base depth split |
| Dust or water test record | None published; both fields recorded as unmeasured | None published; both fields recorded as unmeasured | A priced accredited test scope against the ordered configuration, if a figure is required |
| Gasket compound | EPDM or an equivalent compressible gasket, offered as a manufacturer option | Not applicable; no closure is offered on the shell | Compound, cross-section and the replacement route for service |
| Pressure equalisation valve | Manufacturer option on every model, not fitted as standard | Manufacturer option on every model, not fitted as standard | Whether the duty involves altitude or repeated temperature swing |
| Interior volume published | 0.8 L to 139.5 L internal, with usable interior volume stated separately | 0.3 L to 50.4 L internal, with usable interior volume stated separately | Usable volume after the intended foam, on the same drawing as the case |
| Temperature and UV figures | Recorded as unmeasured across the range | Recorded as unmeasured across the range | Either your own exposure test or a material statement, never an assumed rating |

## Step four: size the interior so the closure is used properly

Most closures fail in use for reasons that have nothing to do with the gasket. Foam that is too thick holds the lid off its rim. A cable pushed into the parting line keeps a corner open. A document pocket stuffed under the seal does the same thing. So size from the published usable interior volume rather than the internal box, and check it against your packed kit including connectors, handles, antennae and anything that stands proud. Our model pages publish internal volume and usable interior volume separately for precisely this reason, and the difference between the two on a deep shell can be several litres once the wall and lid split are taken out.

The published narrow internal width matters more than buyers expect, because it is the tightest point inside the shell and often the one nearest the seal. KX-1905 lists 180 mm by 160 mm internally but a 130 mm narrow width, and KX-1204 lists 115 mm by 78 mm with a 70 mm narrow figure. A kit that fits the floor dimensions can still hold the lid off its rim at that pinch point, and the gap that appears is exactly where dust enters. Where a model publishes a narrow figure, use it as your clearance limit and allow room for the foam on every face rather than only under the lid.

Then choose the foam as a dust surface. Pick-and-pluck, die-cut and CNC-cut layouts are all available on every model in the range, in cross-linked PE, EVA or EPS by zone. For a dusty duty the decisions are whether the cell structure is closed, whether any cut edge is exposed at the parting line, and whether the surface can be wiped without shedding. Custom foam can be ordered from a single unit, and we ask for a drawing, a photograph of the packed kit, or a physical sample, because a foam layout is only reviewable when the actual geometry of what is being protected is visible.

## Step five: decide what you will verify, and on whose cost

Put acceptance into the order before the goods move, and split it into what you can check yourself and what you must pay to measure. Incoming inspection on a moulded case is quick and genuinely predictive: sight down the lid edge for a uniform gap, run a finger around the channel for a continuous gasket with no splice sitting at a latch point, close the case on a strip of paper at four positions and feel the pull, check that the latches draw the lid down without distortion, and confirm the wall thickness against the published figure. Those checks cost nothing and they catch the moulding and assembly faults that matter for dust.

A measured ingress figure is a different purchase. Where a rating is a contractual requirement, we quote accredited testing against the specific model and configuration as a separate work package, because no test record exists on any of the 155 catalogue models and inventing one would be worse than declaring none. The buyer who budgets that package at quotation stage gets a clean answer; the one who discovers the requirement after tooling gets a report on a sample rather than on the production units, which is the situation that ends relationships.

Finally, keep the verification loop where the failure would be visible. If the case is used on a site, ask whoever opens it whether the rim was clean, not whether the case looked fine. Grit in a channel is a maintenance finding, and the Dust Protection page in our quality section lists a cleanable channel geometry as a design requirement for exactly that reason. A five-minute question asked monthly tells you more about your real dust performance than any figure copied from a datasheet.

## How a good supplier answer reads, and how a weak one reads

A good answer in this category is specific and slightly boring. It names a model, gives the closure construction and the wall thickness, states the latch plan, distinguishes internal from usable volume, says plainly which items are configuration options, and says plainly what has not been tested and what testing would cost. It offers a first article you can inspect before a batch is committed, and it puts the test scope in writing if you need a number. Every one of those is available in our published data because those are the fields we record per model.

A weak answer is a photograph, a standard number and an adjective. If a quotation states an ingress code without naming the test, the laboratory and the tested configuration, treat it as unverified and say so in writing before you rely on it. If it offers a rating for a whole product family rather than the ordered shell, it is describing a hope. And if the interior is quoted as a lump sum without a cut drawing, nobody has yet decided where your dust will settle, which is the question the interior has to answer.

## Where each group fits: duties worth specifying for

For instrument, survey and laboratory kits that travel between controlled rooms, the selection question is usually abrasion and cleanliness rather than airborne fines, and a well-fitted unsealed shell with a closed-cell interior is often the right commercial answer. KX-1204 at 120 x 90 x 40 mm with a 2.6 mm wall is an accessory and small-optics box; KX-4710 at 466 x 387 x 102 mm with a 2.5 mm wall carries larger flat kit on a shelf. Both publish that no sealed closure is offered, and that statement is the reason to choose or reject them honestly.

For field electronics, communications and test equipment that is opened where the work is happening, specify from the gasketed group and let volume decide the shell. KX-1905 and KX-62109 cover small instrument sets at 1.2 L and 2.0 L with a 3.0 mm wall; KX-4010 and KX-65522 cover mid-size kits at 10.8 L and 37.1 L; KX-97227 and the rolling KX-88442 cover deployed sets at 53.9 L and 139.5 L with wheels and a telescopic handle, where the seal has to survive being upright on a loading bay.

For industrial, worksite and quarry duties, the failure mode is usually the rim and the latch line rather than the gasket, so specify the latch count, the channel geometry and a foam cut that leaves nothing proud at the parting line. Ammunition-style storage boxes are a useful reference class here because all 20 models in that group publish the same gasketed closure and are ordered for long static storage where a seam must stay closed for months rather than survive a drop.

## Customising and OEM: what a buyer should plan around

If the standard shells do not fit the dust duty, the changes worth asking for are the ones that touch the closure: gasket compound, valve bore, latch count and position, parting-line geometry, and a shell material change. Shell material is published per model, with PP on 94 models, engineering PP on 38, ABS on 22 and one model listed as PP or ABS by configuration. Gasket compound is offered as EPDM or an equivalent compressible material, and a pressure equalisation valve is an option on every model in the range. None of this requires a new mould, which is why it is worth specifying before you start talking about tooling.

A new mould is the last resort and it should be budgeted, not assumed. Our standing figures are 45 days for first articles on an existing mould and 125 days for a new mould, with a minimum order from 3,000 per component on custom moulding. Logo, colour and OEM work start at 300 units; a standard shell and custom foam can both be ordered from a single unit, which makes a physical trial of your closure assumption cheap enough to be obligatory.

The commercial frame matters to the same plan. We sell wholesale and OEM only, on EXW or FOB terms, with no retail channel, no delivery-duty-paid service and no overseas warehouse stock, and third-party inspection is welcome. That means your quality function can verify the closure at the factory before the containers move, which is the cheapest point in the whole supply chain to find a short gasket or a misplaced latch boss.

## Procurement notes and the limits of what any catalogue can promise

Write the requirement as a set of inspectable facts and the purchase stops being a bet. On the request for quotation, put the model number, the closure statement you expect, the wall thickness, the latch plan, the internal and usable volume you need, the foam type and cut, and the verification you intend to perform. Put the accredited test scope on the same document as a priced option, or state that no rating is required and that construction plus incoming inspection is your acceptance basis. Either answer is defensible; an unstated one is not.

Pricing follows from the same structure. A standard shell is a tool you already own the cost of; a foam cut is a single-unit change; a logo or colour is a 300-unit decision; a new latch position or valve bore may be a tooling change; and a new mould is a 125-day, 3,000-unit commitment. The mistake that makes dust-resistant cases expensive is choosing the last two options to solve a problem that a clean rim, a correct latch count and a closed-cell cut would have solved at the first level.

And say the quiet part in the specification too: no seal survives a dirty rim, and no case protects equipment that is packed wet or packed with grit already on it. A written habit of wiping the channel and the lid face before closing, of letting a cold case acclimate before it is opened in a warm room, and of replacing a gasket that has taken a permanent set will change your dust results more than the next specification revision will. We publish what is built; how it is used is the other half of the claim.

![Custom foam liner being prepared for a protective case](https://kexincases.com/assets/img/pool/foam-liner-33-900.webp)Custom foam liner being prepared for a protective case

![Custom foam liner being prepared for a protective case](https://kexincases.com/assets/img/pool/foam-liner-52-900.webp)Custom foam liner being prepared for a protective case

![Custom foam liner being prepared for a protective case](https://kexincases.com/assets/img/pool/foam-liner-65c-900.webp)Custom foam liner being prepared for a protective case

![Custom foam liner being prepared for a protective case](https://kexincases.com/assets/img/pool/foam-liner-08-900.webp)Custom foam liner being prepared for a protective case

## Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

## Procurement considerations

| Question | What to send us |
|---|---|
| Which shell fits? | Equipment L × W × H as packed, plus required clearance per axis |
| What does it cost? | Order quantity and estimated annual quantity — the two drive different answers |
| Is tooling needed? | Whether an existing shell clears the envelope with usable foam depth |
| Lead time? | Your required delivery date, not just the order date |
| Certification? | The exact standard your tender names — we will say whether we can test to it |
| Freight? | Destination and preferred terms; carton and pallet data supplied with the quotation |

## Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

| Situation | What To Do |
|---|---|
| Occasional splash | A close-fitting rim without a gasket is cheaper and easier to maintain. |
| Rain and washdown | Sealed configuration, four or more latches, stainless hardware. |
| Immersion or pressure change | Sealed configuration plus a pressure-equalisation valve, and a documented test. |

- Size on internal dimensions plus clearance, never on a product name.
- Choose the carrying method before the shell: it changes the series, not just the price.
- Specify the interior last, and decide up front whether the end user will reconfigure it.

How should buyers select a dust-resistant protective case? relates to Waterproof & Dustproof Guide. Related families: Waterproof Cases / Instrument & Equipment Cases / Electronics Cases / Field Equipment Cases / Military Protective Cases / Outdoor Protective Cases / Ammunition Storage & Transport Boxes / Rolling Cases / Custom Protective Cases. Related sectors: field and industrial equipment. Continue in the Waterproof & Dustproof Guide cluster.

Entity relationships

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

[Talk To The Manufacturer→](https://kexincases.com/request-a-quote/)[Find the Right Case](https://kexincases.com/find-your-case/)

Next step

Waterproof & Dustproof Guide · Procurement

## Frequently asked on this topic

How should buyers select a dust-resistant protective case?In five steps, in this order: describe the dust and the handling cycle; read the supplier's closure statement and, separately, its test status; check the geometry that keeps the closure compressed, which means wall thickness, parting-line continuity and latch plan; size the interior from usable volume and the narrow dimension at the rim so the lid actually closes; and decide what you will verify on incoming inspection versus what you will pay an accredited laboratory to measure. A case selected this way is chosen on inspectable facts rather than on an adjective.Which of your cases are dust resistant?We describe construction rather than a rating. 124 of our 155 published models record a compressible gasket in a continuous moulded channel as a measured construction feature, and 31 record that no sealed closure is offered on that shell. The dust-resistance and waterproof fields are recorded as unmeasured on all 155 models, and no ingress protection code is stated anywhere in the catalogue. Where a stated figure is contractually required, accredited testing against the exact model and configuration is quoted as a separate work package.Is wall thickness really part of a dust specification?Yes, because a gasket works by being compressed against a rim that stays flat. Every gasketed model in our range publishes a wall thickness of 3.0 mm or more, up to 6.0 mm, while the unsealed group publishes 2.0 mm to 2.9 mm where a figure exists. A thin shell flexes under the latches, under stack load and when it is carried by the handle, and that movement opens the channel. This is why the two numbers should appear together on your shortlist, and why we publish wall thickness per model.What should go in the request for quotation for a dust-resistant case?The model number, the closure construction you expect, the wall thickness, the lid and base depth split, the internal and usable volume you need, the narrow internal width as your clearance limit, the latch count and position, the gasket compound, whether a pressure equalisation valve is wanted, the foam type and cut, your incoming inspection points, and either a priced accredited test scope or an explicit statement that construction plus inspection is your acceptance basis. Add a drawing, a photograph of the packed kit or a sample so the interior can be reviewed.Can a sealed case overheat the equipment inside it?It can, so treat heat and ingress as one selection. A closed cavity around a warm device limits how heat escapes, and the useful controls are interior volume, foam layout and duty cycle rather than a heavier gasket. We publish internal volume and usable interior volume separately on each model page, from 0.8 L up to 139.5 L, so the space left after the foam is designed is visible. Tell us at quotation stage if equipment runs warm or is packed warm, because that changes both the interior and whether a valve bore is worth specifying.What are the minimum order quantities and lead times for custom work?A standard shell can be ordered from one unit, as can custom foam. Logo, colour and OEM work start at 300 units. A new mould starts at 3,000 units per component. First articles on an existing mould take 45 days and a new mould takes 125 days, which is the planning window for any change to the parting line, latch position or valve bore. This is a wholesale and OEM business on EXW or FOB terms, with no retail, no delivery-duty-paid service and no overseas warehouse; third-party inspection is welcome before shipment.

## Continue in Waterproof & Dustproof Guide

Related

[TECHNICALHow Waterproof Cases Actually Work](https://kexincases.com/knowledge-center/how-waterproof-cases-work/)[KNOWLEDGEWhat An IP Rating Does Not Tell You](https://kexincases.com/knowledge-center/what-ip-rating-does-not-tell-you/)[TECHNICALPressure Equalisation Valves Explained](https://kexincases.com/knowledge-center/pressure-equalisation-valves-explained/)[TECHNICALWhat environmental factors should be considered for electronic equipment transport?](https://kexincases.com/knowledge-center/what-environmental-factors-should-be-considered-for-electronic-equipment-trans/)[TECHNICALHow Do Field Cases Protect Equipment From Dust And Moisture?](https://kexincases.com/knowledge-center/how-do-field-cases-protect-equipment-from-dust-and-moisture/)[KNOWLEDGEWhat Is Impact Testing?](https://kexincases.com/knowledge-center/what-is-impact-testing/)[KNOWLEDGEWhat Is a Waterproof Protective Case?](https://kexincases.com/knowledge-center/what-is-a-waterproof-protective-case/)[KNOWLEDGEWhat Is a Shockproof Protective Case?](https://kexincases.com/knowledge-center/what-is-a-shockproof-protective-case/)[KNOWLEDGEWhat Is Waterproof Testing?](https://kexincases.com/knowledge-center/what-is-waterproof-testing/)[KNOWLEDGEWhat Is a Dustproof Equipment Case? The Closure That Keeps Grit Out](https://kexincases.com/knowledge-center/what-is-a-dustproof-equipment-case/)[KNOWLEDGEWhat Is Drop Testing? The Procedure, What It Measures and What We Publish](https://kexincases.com/knowledge-center/what-is-drop-testing/)[TECHNICALHow Do Outdoor Cases Protect Equipment From Environmental Conditions?](https://kexincases.com/knowledge-center/how-do-outdoor-cases-protect-equipment-from-environmental-conditions/)[TECHNICALWhy Is Waterproof Protection Useful for Outdoor Equipment? The Damage Water Does Before You Notice](https://kexincases.com/knowledge-center/why-is-waterproof-protection-useful-for-outdoor-equipment/)[TECHNICALWhy Is Dust Protection Important For Electronic Equipment?](https://kexincases.com/knowledge-center/why-is-dust-protection-important-for-electronic-equipment/)[PROCUREMENTWhat Combination Of Protection Features Should Buyers Consider?](https://kexincases.com/knowledge-center/what-combination-of-protection-features-should-buyers-consider/)[PROCUREMENTWhy Should Buyers Ask Manufacturers About Testing Methods?](https://kexincases.com/knowledge-center/why-should-buyers-ask-manufacturers-about-testing-methods/)[PRODUCTWhat Environmental Protection Should Field Equipment Cases Provide?](https://kexincases.com/knowledge-center/what-environmental-protection-should-field-equipment-cases-provide/)[TECHNICALHow Should Waterproof Case Seals Be Maintained? The Four Checks That Stop Field Leaks](https://kexincases.com/knowledge-center/how-should-waterproof-case-seals-be-maintained/)[PRODUCTHow Are Protective Cases Tested? Six Stages, Four Owners, and What Each Proves](https://kexincases.com/knowledge-center/how-are-protective-cases-tested/)[PROCUREMENTWhat should buyers check before purchasing a waterproof case?](https://kexincases.com/knowledge-center/what-should-buyers-check-before-purchasing-a-waterproof-case/)[TECHNICALHow should sensitive equipment be secured inside a case?](https://kexincases.com/knowledge-center/how-should-sensitive-equipment-be-secured-inside-a-case/)[TECHNICALHow should equipment cases be selected for outdoor transportation?](https://kexincases.com/knowledge-center/how-should-equipment-cases-be-selected-for-outdoor-transportation/)[TECHNICALHow Do Seals Help Reduce Dust Entry?](https://kexincases.com/knowledge-center/how-do-seals-help-reduce-dust-entry/)[TECHNICALHow Does Foam Reduce Impact Transmission?](https://kexincases.com/knowledge-center/how-does-foam-reduce-impact-transmission/)[PRODUCTWhat affects case seals for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-seals-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case gaskets for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-gaskets-for-equipment-transport-cases/)[PRODUCTWhat Equipment Benefits From Dustproof Cases? The Five Groups That Pay for the Closure](https://kexincases.com/knowledge-center/what-equipment-benefits-from-dustproof-cases/)[PRODUCTWhat Affects The Impact Protection Of A Case? Six Factors, Ranked](https://kexincases.com/knowledge-center/what-affects-the-impact-protection-of-a-case/)[OEMCan Shockproof Cases Be Customized?](https://kexincases.com/knowledge-center/can-shockproof-cases-be-customized/)[PRODUCTWhat Environmental Factors Affect Protective Case Selection? Five Drivers, Ranked](https://kexincases.com/knowledge-center/what-environmental-factors-affect-protective-case-selection/)[TECHNICALHow Do Temperature Changes Affect Equipment Cases? Six Mechanisms](https://kexincases.com/knowledge-center/how-do-temperature-changes-affect-equipment-cases/)[TECHNICALHow Does a Waterproof Case Protect Equipment?](https://kexincases.com/knowledge-center/how-does-a-waterproof-case-protect-equipment/)[OEMCan Waterproof Cases Be Customized?](https://kexincases.com/knowledge-center/can-waterproof-cases-be-customized/)[TECHNICALHow Can Protective Cases Be Used in Harsh Environments?](https://kexincases.com/knowledge-center/how-can-protective-cases-be-used-in-harsh-environments/)[KNOWLEDGEIP Rating Selection for Communication Cases](https://kexincases.com/knowledge-center/ip-rating-selection-for-communication-cases/)[KNOWLEDGEKayak/surfboard Sealed Waterproof Dry Case](https://kexincases.com/knowledge-center/kayak-surfboard-sealed-waterproof-dry-case/)[KNOWLEDGESolar Panel Tester Portable Waterproof Case](https://kexincases.com/knowledge-center/solar-panel-tester-portable-waterproof-case/)[KNOWLEDGEDustproof and Waterproof Instrument Case Design](https://kexincases.com/knowledge-center/dustproof-and-waterproof-instrument-case-design/)[KNOWLEDGEDustproof and Waterproof Medical Case Design](https://kexincases.com/knowledge-center/dustproof-and-waterproof-medical-case-design/)[KNOWLEDGEDustproof and Waterproof Photography Case Design](https://kexincases.com/knowledge-center/dustproof-and-waterproof-photography-case-design/)[![Waterproof Cases](https://kexincases.com/assets/img/app/shockproof.webp)PRODUCT FAMILYWaterproof Cases](https://kexincases.com/products/waterproof-cases/)[![Instrument & Equipment Cases](https://kexincases.com/assets/img/app/instrument.webp)PRODUCT FAMILYInstrument & Equipment Cases](https://kexincases.com/products/instrument-cases/)[![Electronics Cases](https://kexincases.com/assets/img/app/electronics.webp)PRODUCT FAMILYElectronics Cases](https://kexincases.com/products/electronics-cases/)
