# What Affects Case Load Capacity for a Hard-Shell Equipment Case?

> What affects case load capacity on a hard-shell equipment case: footprint, wall, material, lid split and stackable design, and why we publish no stack figure.

Human-readable page: https://kexincases.com/knowledge-center/what-affects-case-load-capacity-for-a-hardshell-equipment-case/
Site overview for AI agents: https://kexincases.com/llms.txt

## Page content

Case load capacity is set by the geometry and build of the shell, not by one stamped number, and on our own catalogue that number is deliberately absent: none of our 155 active models publishes a stack-load or load-capacity value, because no test record exists for that configuration. What we publish instead, and what actually governs how a case behaves under a stack, is the load path. Four things dominate it. First the footprint and rim: the outside plan area of the shell (from about 0.011 square metres on KX 1204 to about 0.50 square metres on KX 88442) and the locating lip that carries a stack, not the flat lid panel. Second wall thickness, which we publish per model across 148 models from 2.0 mm to 6.0 mm with a median of 3.9 mm. Third shell material and moulding: 94 polypropylene, 38 engineering polypropylene and 22 ABS shells. Fourth the lid and base split, published on 100 models with lid depth from 16 mm to 320 mm. Stackability itself is a design flag, not a rating: 136 models are published stackable and the 19 T-series trolleys are published non-stackable. A real load figure is a tested property, so read these published inputs, not a headline claim.

Quick answer

### Key points

- On our 155 active models the stack-load and load-capacity fields are recorded as not measured, so we publish no kilogram figure rather than an untested one.
- Four published inputs govern load behaviour: external footprint and locating rim, wall thickness, shell material, and the lid and base depth split.
- Stackable is a design flag, not a strength rating: 136 models publish stackable and the 19 T-series trolleys publish non-stackable.
- Wall thickness is a manufacturing fact we measure (2.0 to 6.0 mm, median 3.9 mm) but it is not a load certificate on its own.
- Net weight is not capacity: 93 models publish a finished empty-case mass from 0.10 kg to 15.32 kg, which says nothing about a stack limit.
- Pallet quantity and container loading are not stamped either; they are computed from the carton footprint against your pallet and shipped with the quote.
- Where a tender needs a number, we commission accredited third-party testing of the exact configuration as a separate work package.

## What actually sets case load capacity on a hard-shell case

The honest starting point is that a load capacity is not a property you can read off a datasheet line, and it is certainly not a property you can infer from a heavier shell. It is the outcome of a test: someone puts a known mass on a known configuration for a known time and records whether the shell, the rim, the latches or the lid take it. Because we have not run that test on our catalogue, none of our 155 active models carries a published stack-load or load-capacity value; those two fields are recorded as not measured. What we can tell you, and what determines how a case will behave before any test is run, is the load path, which is set by four families of published numbers.

The first family is geometry: the outside plan area of the shell, the locating rim that receives the case above it, and the height that decides how many units go into a column. The second is the wall: our published wall thickness spans 2.0 mm to 6.0 mm across the 148 models that list it, with a median of 3.9 mm, and thickness multiplies with area rather than adding to it. The third is material and moulding design, since 94 polypropylene, 38 engineering polypropylene and 22 ABS shells deform differently at the same wall. The fourth is the lid and base split, published on 100 models, which decides where a vertical load is carried and whether the weak point is the lid panel or the rim.

## The published inputs behind a load figure, field by field

Before you ask any supplier for a stack rating, ask what the rating is built on. The table below lists the specification fields we publish per model and states plainly what each one does and does not tell you about load capacity. Every figure is a per-model published value from our own specification file; none of them is a generalised claim about the whole range, and none of them is a load rating.

| Field | Published | Governs |
|---|---|---|
| External footprint | Yes, per model | Plan area and rim that receives the case above |
| Wall thickness | 148 of 155 models, 2.0 to 6.0 mm | Shell stiffness and the load path through the wall |
| Shell material | PP / Engineering PP / ABS | How the same wall deflects and recovers under load |
| Lid and base depth | 100 models, lid 16 to 320 mm | Whether the rim or the lid panel carries a stack |
| Stackable flag | 136 stackable, 19 non-stackable | Design intent, not a measured kilogram limit |
| Load capacity / stack load | Not measured on any model | A tested value we will not invent |

## Wall thickness and material: what they explain and what they do not

Wall thickness is the most comparable published number, so buyers reach for it first, but it behaves as one input, not as a certificate. A 6.0 mm wall on a 662 by 495 mm box such as KX 6621 is a different structure from a 6.0 mm wall on a 720 by 500 mm box such as KX 97227, even though both list the same thickness and both use engineering polypropylene. Material matters just as much: our file lists 94 polypropylene shells, 38 engineering polypropylene shells and 22 ABS shells, and at an equal wall the denser ABS and the tougher engineering grades deflect less. The point is that thickness is a manufacturing fact you can put a calliper on, which is why we publish it, whereas a load limit is a behaviour you can only get from a rig.

The same caution applies in reverse. A thin wall is not automatically fragile: the 2.0 mm shells such as KX 2005 are compact utility boxes with a short span between ribs, and a deep 3.0 mm lid on a large body can flex more than a shallow wall on a small one. When you compare two cases, compare thickness against the unsupported span and the rim, not thickness on its own. If a specification asks you to treat a millimetre figure as a stacking rating, that is the wrong instrument for the question.

## Stackable is a design flag, not a load rating

We publish a stackable field because it is a real design decision: a shell either has the rim, feet and base geometry to sit on another shell, or it does not. Across our catalogue 136 models are published stackable and 19 are published non-stackable, and those 19 are exactly the T-series trolleys, whose wheel housings, telescopic handle and reinforcing frame give them a base that is not meant to receive weight from above. That distinction is useful for racking and for how a shipment is cubed, but it is a yes-or-no flag, not a number, and it does not tell you how many kilograms a stack will carry.

The two flags can also disagree with the wall, which is why they must be read together. KX 88421 at 843 by 592 by 212 mm is published stackable; KX 88442 at 843 by 592 by 415 mm shares the same footprint, the same 5.0 mm published wall and the same polypropylene shell, yet it is published non-stackable because the taller body changes the load path and the racking behaviour. Neither listing implies a maximum load. A stackable flag tells you a design is intended to be piled; a load figure would tell you how far, and we do not stamp one without a test.

## Same wall, same material, different stackability: three matched models

The following rows are drawn straight from our specification file to make one point concrete: the published geometry and material of a case do not map onto a single stackability outcome, and none of the columns contains a load rating because we do not publish one. Read the last column as the answer to the question a datasheet line cannot give you.

| Model | External Mm | Wall | Material | Stackable | Load Figure |
|---|---|---|---|---|---|
| KX 6621 | 662 x 495 x 210 | 6.0 mm | Engineering PP | Stackable | Not published |
| KX 97227 | 720 x 500 x 270 | 6.0 mm | Engineering PP | Non-stackable | Not published |
| KX 88421 | 843 x 592 x 212 | 5.0 mm | PP | Stackable | Not published |
| KX 88442 | 843 x 592 x 415 | 5.0 mm | PP | Non-stackable | Not published |

## How to read what you have before you buy

If your real question is whether a case will survive being stacked in a container or on a rack, work down the published fields in a fixed order. Start with footprint and rim, because that is where an upper case lands, not on the flat lid. Then check the lid and base split, published on 100 models with lid depths from 16 mm to 320 mm: a shallow lid on a deep base puts the load through the rim, while a deep lid can put it through the panel you least want to compress. Check the wall thickness and the material together, then read the stackable flag to confirm the design is even intended to be piled. Finally check the external height, because that sets how many units go into a column and therefore how tall a stack you are really building.

Then separate the fields that describe the case from the fields that describe freight. Net weight is a case property, not a capacity: 93 models publish a finished empty-case mass from 0.10 kg to 15.32 kg with a median of 1.48 kg, and a heavier case is not a case that carries more. Pallet quantity and container loading are logistics properties: both are recorded as not measured on all 155 models, because we calculate pallet fit from the carton footprint against your pallet size and supply 20GP, 40GP and 40HQ figures with the quotation rather than stamp a generic value on the shell. Where you genuinely need a stack rating, ask us to commission accredited third-party testing of the exact configuration and treat the result as covering that configuration only.

## Applications and where a load figure actually matters

Most of our hard-shell cases ship as single units, in a carton, and the stacking that matters is warehouse and container stacking of cartons rather than shell-on-shell piles. That is where the published external dimensions, the pieces-per-carton field (58 models publish it, from 1 to 40 pieces) and the carton size do the work, and where we compute pallet and container loading with your numbers. Where shell-on-shell stacking is a real requirement, it is usually field equipment staged in a depot, industrial instruments racked in a plant, or military and electronics cases palletised for transport, and those are the cases where we should be discussing a test, not a brochure figure.

For rolling and wheeled bodies the answer is simpler: the 19 T-series trolleys are published non-stackable, so the design intent is to move a single load by hand, not to carry a column. Describing them as stackable, or borrowing a stack figure from a rigid box of similar volume, would be wrong in both directions. The right move for those models is to size the case to the equipment, palletise it as a single unit, and treat stacking as out of scope.

## Customising the case for a load requirement

A load requirement is usually met through configuration, not by inventing a number. On an existing mould we can change the interior (a pick-and-pluck, die-cut, CNC-cut, EVA, PE or EPE layout quoted against your drawing, with drawing or sample required before production), the seal and hardware set (latches, feet, padlock-ready bodies), and the colour or logo programme. Standard cases and custom foam carry an MOQ of 1 unit; logo, colour and OEM work start at 300 units; first samples against an existing mould run about 45 days. What an existing mould cannot do is relocate the rim or thicken the wall, because those are steel.

If the real need is a different load path, the conversation ends in new tooling: about 125 days, MOQ from 3,000 units per component, a 30 percent deposit with the balance after your inspection, EXW or FOB. We work wholesale and OEM or ODM only, with no retail, no delivered-duty-paid terms and no overseas warehouse stock, and inspection agents and third-party factory audits are welcome on site. Send the footprint, the stacked height, the configuration and the figure a tender is asking you to meet, and we will answer with the published geometry for the specific model, an explicit statement that the stack-load field is not measured, and a quote for accredited testing of that configuration if you need a number on paper. Signature: KeXin New Materials (Guangdong) Co., Ltd.

![Protective case used for outdoor and vehicle equipment](https://kexincases.com/assets/img/pool/outdoor-case-17-900.webp)Protective case used for outdoor and vehicle equipment

![Protective case used for outdoor and vehicle equipment](https://kexincases.com/assets/img/pool/outdoor-case-01-900.webp)Protective case used for outdoor and vehicle equipment

![Protective case used for outdoor and vehicle equipment](https://kexincases.com/assets/img/pool/outdoor-case-03-900.webp)Protective case used for outdoor and vehicle equipment

![Protective case used for outdoor and vehicle equipment](https://kexincases.com/assets/img/pool/outdoor-case-05-900.webp)Protective case used for outdoor and vehicle equipment

## Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

## Procurement considerations

| Question | What to send us |
|---|---|
| Which shell fits? | Equipment L × W × H as packed, plus required clearance per axis |
| What does it cost? | Order quantity and estimated annual quantity — the two drive different answers |
| Is tooling needed? | Whether an existing shell clears the envelope with usable foam depth |
| Lead time? | Your required delivery date, not just the order date |
| Certification? | The exact standard your tender names — we will say whether we can test to it |
| Freight? | Destination and preferred terms; carton and pallet data supplied with the quotation |

## Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

| Situation | What To Do |
|---|---|
| Fastest | Standard shell plus CNC foam — typically 45 days from approved drawing. |
| Branded | Standard shell plus custom colour and logo — MOQ applies to the resin colour. |
| Bespoke geometry | New mould — 125 days, MOQ from 3,000 units per component. |

- Size on internal dimensions plus clearance, never on a product name.
- Choose the carrying method before the shell: it changes the series, not just the price.
- Specify the interior last, and decide up front whether the end user will reconfigure it.

What affects case load capacity for a hard-shell equipment case? relates to Logistics & Packing Guide. Related families: Custom Protective Cases / Equipment Transport Cases / Military Protective Cases / Tactical Equipment Cases / Rolling Cases / Field Equipment Cases / Electronics Cases / Tool Cases. Related sectors: field and industrial equipment. Continue in the Logistics & Packing Guide cluster.

Entity relationships

![One case closed flat and a second turned over beside it to show the moulded locating lip and ribbed walls that carry a stack](https://kexincases.com/assets/img/ai/what-affects-case-load-capacity-for-a-hardshell-equipment-case-900.webp)Illustrative rendering Illustrative rendering of a typical configuration, not a photograph of the shipped item. Dimensions and materials on this page come from our published model data.

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

[Talk To The Manufacturer→](https://kexincases.com/request-a-quote/)[Find the Right Case](https://kexincases.com/find-your-case/)

Next step

Logistics & Packing Guide · Product

## Frequently asked on this topic

What affects case load capacity for a hard-shell equipment case?Four published families govern it: the external footprint and locating rim, wall thickness (2.0 to 6.0 mm across the 148 models that list it, median 3.9 mm), shell material and moulding design (94 PP, 38 engineering PP, 22 ABS), and the lid and base split (published on 100 models, lid depth 16 to 320 mm). Stackability is a design flag, with 136 models published stackable and the 19 T-series trolleys non-stackable. A load figure itself is a tested value we do not publish.Do you publish a stack load or load capacity number for your cases?No. On all 155 active models the stack-load and load-capacity fields are recorded as not measured, and we will not print a kilogram figure we have not tested. What we do publish per model is the geometry and build that determine how a case behaves under a stack, plus the stackable design flag. Where a tender needs a number, we quote accredited third-party testing of the exact configuration as a separate work package, and the result covers that configuration only.Is a thicker wall a higher load capacity?Not on its own. Wall thickness multiplies with the unsupported span and the rim, and material changes the answer at the same thickness. Two of our models both publish 6.0 mm walls and both use engineering polypropylene, yet one is published stackable and one is not, because the footprint and body depth differ. Treat a millimetre figure as one input to read alongside the rim and the material, never as a stacking rating.Can I use case weight to judge how much a case can carry?No. Net weight is a case property, not a capacity. Across the 93 models that publish a finished empty-case mass, the range is 0.10 kg to 15.32 kg with a median of 1.48 kg, and a heavier shell is not a shell that holds more load. Freight fields are separate again: pallet quantity and container loading are recorded as not measured on every model because they are calculated from the carton footprint against your pallet and supplied with the quotation.What does the stackable flag actually tell me?It tells you the design intent of the base and rim, not a measured limit. We publish 136 models as stackable and 19 T-series trolleys as non-stackable because the wheel housings and frame on the trolleys are not built to receive weight from above. A stackable flag says a case can be piled; it does not say how high or under how many kilograms, and you should not borrow a figure from a similar box to fill that gap.

## Continue in Logistics & Packing Guide

Related

[TECHNICALInternal Versus External Dimensions](https://kexincases.com/knowledge-center/internal-vs-external-dimensions/)[TECHNICALHow To Measure Equipment For A Case](https://kexincases.com/knowledge-center/how-to-measure-equipment-for-a-case/)[PROCUREMENTContainer Loading For Protective Cases](https://kexincases.com/knowledge-center/container-loading-for-protective-cases/)[KNOWLEDGEHow To Read A Protective Case Datasheet](https://kexincases.com/knowledge-center/how-to-read-a-protective-case-datasheet/)[TECHNICALStacking and Palletising Protective Cases](https://kexincases.com/knowledge-center/stacking-and-palletising-protective-cases/)[KNOWLEDGEHow can protective cases improve equipment organization?](https://kexincases.com/knowledge-center/how-can-protective-cases-improve-equipment-organization/)[PROCUREMENTWhat Factors Affect Shipping Costs for Protective Cases?](https://kexincases.com/knowledge-center/what-factors-affect-shipping-costs-for-protective-cases/)[LOGISTICSHow Can Case Size Affect Logistics Efficiency?](https://kexincases.com/knowledge-center/how-can-case-size-affect-logistics-efficiency/)[LOGISTICSHow Should Equipment Cases Be Palletized? A Carton-First Method](https://kexincases.com/knowledge-center/how-should-equipment-cases-be-palletized/)[LOGISTICSWhat factors affect protective case selection for logistics?](https://kexincases.com/knowledge-center/what-factors-affect-protective-case-selection-for-logistics/)[COMPARISONHow Do Buyers Compare Protective Case Dimensions Across Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-protective-case-dimensions-across-protective-case-suppli/)[COMPARISONHow do buyers compare case weight across protective case suppliers?](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-weight-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Handles Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-handles-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Seals Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-seals-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Gaskets Across Protective Case Suppliers? The Bead, The Channel, The Closure](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-gaskets-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Hinges Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-hinges-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Latches Across Protective Case Suppliers? A Closure-Geometry Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-latches-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Load Capacity Across Protective Case Suppliers? A Field-by-Field Audit](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-load-capacity-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Wheels Across Protective Case Suppliers? A Published-Field Audit](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-wheels-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Stackability Across Protective Case Suppliers? A Field-by-Field Guide](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-stackability-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Palletization Across Protective Case Suppliers? A Field-by-Field Guide](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-palletization-across-protective-case-suppliers/)[TECHNICALHow Should Field Research Equipment Be Transported? A Packing Method From The Factory](https://kexincases.com/knowledge-center/how-should-field-research-equipment-be-transported/)[TECHNICALWhat Affects Protective Case Dimensions for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-protective-case-dimensions-for-a-hardshell-equipment-case/)[KNOWLEDGECommon Mistakes in Protective Case Dimensions for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-protective-case-dimensions-for-equipment-trans/)[COMPARISONWhat Affects Internal vs External Dimensions for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-internal-vs-external-dimensions-for-a-hardshell-equipment-case/)[KNOWLEDGECommon Mistakes in Internal vs External Dimensions for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-internal-vs-external-dimensions-for-equipment/)[TECHNICALWhat Affects Case Weight for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-case-weight-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat Are The Common Mistakes In Case Load Capacity For Equipment Transport Cases?](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-load-capacity-for-equipment-transport-cas/)[PRODUCTWhat affects case wheels for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-wheels-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case wheels for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-wheels-for-equipment-transport-cases/)[PRODUCTWhat affects case handles for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-handles-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case handles for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-handles-for-equipment-transport-cases/)[KNOWLEDGEWhat are the common mistakes in case weight for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-weight-for-equipment-transport-cases/)[PRODUCTWhat affects case hinges for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-hinges-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case latches for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-latches-for-equipment-transport-cases/)[KNOWLEDGECommon Mistakes in Case Hinges for Equipment Transport Cases: An Eight-Point Field Guide](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-hinges-for-equipment-transport-cases/)[PRODUCTWhat Affects Case Latches for a Hard-Shell Equipment Case? Eight Published Factors](https://kexincases.com/knowledge-center/what-affects-case-latches-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case seals for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-seals-for-equipment-transport-cases/)[PRODUCTWhat affects case gaskets for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-gaskets-for-a-hardshell-equipment-case/)[PRODUCTWhat affects case stackability for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-stackability-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case stackability for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-stackability-for-equipment-transport-case/)[LOGISTICSWhat affects case palletization for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-palletization-for-a-hardshell-equipment-case/)[KNOWLEDGECommon Mistakes in Case Palletization for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-palletization-for-equipment-transport-cas/)[PROCUREMENTHow Should Protective Case Dimensions Be Specified In A Protective Case RFQ?](https://kexincases.com/knowledge-center/how-should-protective-case-dimensions-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat Information Should Be Provided About Protective Case Dimensions Before a Quotation?](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-protective-case-dimensions-before-a/)[PROCUREMENTHow Should Case Weight Be Specified In A Protective Case RFQ?](https://kexincases.com/knowledge-center/how-should-case-weight-be-specified-in-a-protective-case-rfq/)[PROCUREMENTHow should case load capacity be specified in a protective](https://kexincases.com/knowledge-center/how-should-case-load-capacity-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat information should be provided about case load](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-load-capacity-before-a-quotatio/)[KNOWLEDGEIndustrial Tool Transport Case: Sizes, Foam, Mobility](https://kexincases.com/knowledge-center/industrial-tool-transport-case/)[KNOWLEDGECold Chain Equipment Case: What a Shell Can Prove](https://kexincases.com/knowledge-center/cold-chain-equipment-case/)[KNOWLEDGEAutomotive Equipment Transport Packaging Solutions](https://kexincases.com/knowledge-center/automotive-equipment-transport-packaging-solutions/)[KNOWLEDGECommunication Equipment Transport Packaging Solutions](https://kexincases.com/knowledge-center/communication-equipment-transport-packaging-solutions/)[KNOWLEDGEDrone Equipment Transport Packaging](https://kexincases.com/knowledge-center/drone-equipment-transport-packaging/)[COMPARISONInternal vs External Dimensions Before a Quotation](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-internal-vs-external-dimensions-befo/)[PROCUREMENTSpecifying Case Wheels in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-wheels-be-specified-in-a-protective-case-rfq/)[KNOWLEDGEHow To Measure Usable Interior Dimensions](https://kexincases.com/knowledge-center/how-to-measure-usable-interior-dimensions/)[COMPARISONInternal vs External Dimensions in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-internal-vs-external-dimensions-be-specified-in-a-protective-case-r/)[PROCUREMENTWhat information should be provided about case hinges](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-hinges-before-a-quotation/)[PROCUREMENTHow should case latches be specified in a protective RFQ](https://kexincases.com/knowledge-center/how-should-case-latches-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to Send About Case Handles Before a Quotation](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-handles-before-a-quotation/)[PROCUREMENTHow to Specify Case Locks in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-locks-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to Provide About Case Wheels Before a Quote](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-wheels-before-a-quotation/)[PROCUREMENTHow to Specify Case Handles in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-handles-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat information should be provided about case locks](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-locks-before-a-quotation/)[PROCUREMENTHow to specify case hinges in a protective case RFQ](https://kexincases.com/knowledge-center/how-should-case-hinges-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to provide about case latches before a quote](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-latches-before-a-quotation/)[![Custom Protective Cases](https://kexincases.com/assets/img/app/foam-custom.webp)PRODUCT FAMILYCustom Protective Cases](https://kexincases.com/products/custom-protective-cases/)[![Equipment Transport Cases](https://kexincases.com/assets/img/app/trolley.webp)PRODUCT FAMILYEquipment Transport Cases](https://kexincases.com/products/equipment-transport-cases/)[![Military Protective Cases](https://kexincases.com/assets/img/app/military.webp)PRODUCT FAMILYMilitary Protective Cases](https://kexincases.com/products/military-protective-cases/)