# What Affects Protective Case Dimensions for a Hard-Shell Equipment Case?

> Wall thickness, the lid depth and base depth split, taper, hardware and tool family set the numbers on a hard-shell case datasheet, per model.

Human-readable page: https://kexincases.com/knowledge-center/what-affects-protective-case-dimensions-for-a-hardshell-equipment-case/
Site overview for AI agents: https://kexincases.com/llms.txt

## Page content

Five things set the numbers on a hard-shell case datasheet, and none of them is the size of your equipment: the tool family that owns the footprint, the shell wall thickness published for that moulding, the way internal height is split between lid depth and base depth at the parting line, the taper and ribs that make the narrowest interior width smaller than the nominal interior width, and the hardware that projects outside the shell. In the KeXin New Materials (Guangdong) Co., Ltd. catalogue of 155 published models, wall thickness ranges from 2 to 6 mm across the 148 models that publish it, the external-to-internal allowance is a median of 26 mm on length, 57 mm on width and 15 mm on height, and on every one of the 100 models that publishes both lid and base depth the internal height equals lid depth plus base depth exactly. What affects protective case dimensions is therefore the construction, not the label: two cases with the same 315×260 external footprint can hold 4.5 litres or 12.2 litres inside, and a buyer who reads only the outside line will not know which one arrived until the equipment is offered to it.

Quick answer

### Key points

- Read the internal and external dimensions of a hard case as two separate lines; the gap between them is construction, and it is never uniform across the three axes.
- Check the lid depth and base depth split before you check the total: 71 of the 100 models that publish both do not split them evenly.
- Compare the narrowest internal width, not the nominal interior width; on 36 published models the narrow point is up to 37 mm tighter than the box width.
- Wall thickness is published per moulding family (2-6 mm, median 3.7 mm on PP), so a thicker shell buys stacking height by eating interior, not by magic.
- Hardware adds to the envelope, not the cavity: 19 models carry wheels and all 19 of them are marked not stackable, and 11 publish a telescopic handle height of 240-485 mm.
- Judge usable room by published interior litres (17.5 L median against 24.4 L median outside), because the shell share ranges from 13% to 47% of external volume in our own file.
- Freight is decided by carton dimensions and pieces per carton, which 58 of our models publish; case dimensions alone will not price a shipment.

## What affects protective case dimensions before a drawing exists

A hard-shell case is an injection-moulded envelope, so its dimensions are decided by tooling and by the physics of taking a part out of a mould long before any buyer measures a device. The five inputs, in the order they act, are: the tool family, which fixes the footprint and most of the internal length and width; the wall thickness run for that moulding; the parting line, which decides how much of the interior height sits in the lid and how much sits in the base; the draft and the ribs, which create a narrowest internal width below the nominal one; and the hardware package, which adds projection outside the shell without adding a cubic millimetre inside it. Nothing else moves the numbers. Understanding what affects protective case dimensions this way changes the buying conversation: you stop asking what size a case is and start asking which fields the supplier publishes for that specific moulding.

The consequence is that a catalogue line is only meaningful when the fields behind it are present. In our own file, 148 of 155 models publish a wall thickness, 100 publish both lid and base depth, 36 publish a narrowest internal width, 11 publish a telescopic handle height and 58 publish carton dimensions with pieces per carton. Where a field is empty we do not infer it. Protection-related fields - water and dust resistance, stack load, impact - are recorded in the same file as not measured rather than filled with a rating, which is the other half of the discipline: state what is measured per model, and say plainly what is not.

## Driver one: the tool family fixes the footprint, and hard shell equipment case dimensions follow it

The cheapest way to make a range is to keep one set of tools for the length and width and vary only the height, which is exactly what our 3207 family does. KX-3207, KX-3213 and KX-3218 share an external footprint of 315x260 mm and an internal footprint of 308x230 mm, share a wall thickness of 3 mm and share a narrowest internal width of 205 mm; only the vertical build changes. External height runs 70, 128 and 180 mm while internal height runs 64, 118 and 172 mm, and published interior volume goes 4.5, 8.4 and 12.2 litres. Three SKUs, one tool, three capacities. That is why hard shell equipment case dimensions cluster in families in every catalogue, ours included, and why a supplier can offer a tight external width in several depths at no extra tooling cost but cannot offer a different width without a new tool.

The same footprint can still hide two different interiors when the moulding itself differs. KX-2405 and KX-2406 are both 240x200 mm outside with a 2 mm wall, yet KX-2405 gives 220x162 mm inside with a narrowest width of 132 mm, and KX-2406 gives 230x155 mm inside with a narrowest width of 140 mm - longer, narrower and a different lid and base split (18/31 against 25/25 mm). Across our file, 32 footprint groups share an external length and width while the interior differs. The practical rule: never treat an external footprint as a proxy for capacity, and never assume two suppliers with the same outside box give you the same inside box.

## Driver two: shell wall thickness and the gap between internal and external dimensions of a hard case

Subtracting the internal dimensions from the external dimensions is the first arithmetic most buyers try, and it disappoints them because the allowance is not one number. Across all 155 published models the external-minus-internal gap has a median of 26 mm on length, 57 mm on width and 15 mm on height, with the length gap running from 5 to 130 mm and the height gap from 3 to 268 mm. The width gap is systematically the largest because the width axis is where the parting line, the latch bosses, the hinge barrels and the draft all act together. Small models show the effect cleanly: KX-1204 is 120×90×40 outside and 115×78×32 inside on a 2.6 mm wall, a gap of 5/12/8 mm. Large models show the other extreme: KX-97227 is 720×500×270 outside and 590×435×210 inside on the thickest wall in our catalogue, 6 mm, a gap of 130/65/60 mm.

Wall thickness is a published per-model field, not a catalogue-wide constant: 148 models give it, from 2 to 6 mm, and the distribution follows material - PP averages a median of 3.7 mm across 88 models (range 2 to 5), Engineering PP a median of 4.3 mm across 38 models (range 2.1 to 6), ABS a median of 3.9 mm across 22 models (range 3 to 5.3). A buyer comparing two suppliers should ask for the wall figure next to the interior figure, because a thick wall on the same footprint is a smaller case inside, and a thin wall is a case that may not survive being stacked. Seven models in our file carry no published wall value; on those we quote from the moulding rather than assume a number.

| Published Model | External Mm | Internal Mm | Wall Mm | Axis Allowance L/W/H Mm | Interior L |
|---|---|---|---|---|---|
| KX-1204 | 120×90×40 | 115×78×32 | 2.6 | 5/12/8 | 0.3 |
| KX-3207 | 315×260×70 | 308×230×64 | 3 | 7/30/6 | 4.5 |
| KX-4616 | 460×367×155 | 455×338×148 | 3 | 5/29/7 | 22.8 |
| KX-82812 | 275×210×115 | 219×160×100 | 3.4 | 56/50/15 | 3.5 |
| KX-97227 (trolley) | 720×500×270 | 590×435×210 | 6 | 130/65/60 | 53.9 |
| KX-88442 (trolley) | 843×592×415 | 740×518×364 | 5 | 103/74/51 | 139.5 |

## Driver three: the parting line, and why lid depth and base depth matter more than total height

A two-piece shell closes at a parting line, and the interior height is the sum of two separate depths. On all 100 models in our catalogue that publish both fields, the internal height equals lid depth plus base depth exactly - KX-1204 with 16/16 mm gives 32 mm inside; KX-4616 with 74/74 mm gives 148 mm; KX-97227 with 42/168 mm gives 210 mm; KX-88442 with 320/44 mm gives 364 mm. It is an arithmetic identity in our data, not an approximation, which is why we treat the split as a specified dimension rather than a detail. Only 29 of those 100 models split it evenly. The rest are deliberately asymmetric: 71 models have a deeper lid than base, and the ratio reaches 7.27273 to one on KX-88442, where a 320 mm lid depth over a 44 mm base turns a 364 mm internal height into a cavity you can only use if your item is either very short and stored in the base, or hung from the lid.

External height is larger than lid depth plus base depth, by a median of 13.5 mm in our file (range 3 to 268 mm), because the rim, the sealing flange, the gasket groove and - on telescopic models - the intermediate section all live outside the cavity. Buyers who add the two depths and compare the total with the external height will find a few millimetres missing and conclude the datasheet is wrong; it is the construction. When you commission custom foam, the lid and base split is also what determines whether an item sits proud of the parting line, which is where closure interference, gasket crush and latch strain start.

## Driver four: draft, ribs and the narrowest internal width

A moulded wall cannot be perfectly vertical: plastic shrinks as it cools and a part must release from the core, so the walls carry draft, and the corners carry ribs and bosses. The visible result in a datasheet is a second width figure. 36 of our 155 models publish a narrowest internal width, and on those models the narrow point sits a median of 25 mm below the nominal internal width, up to 37 mm lower on the 4710/4713/4716 family, where the interior is 345 mm wide but only 308 mm between the tightest points. KX-1204 is the same story in miniature: 78 mm internal width, 70 mm narrowest.

This matters for exactly the items buyers worry about: a rectangular instrument block, a moulded connector housing, a panel with a protruding collar, a hard drive caddy. If the item has square corners and a rigid body, the fit is decided by the narrow figure and not by the headline one, because the corners of the item meet the tapering part of the wall. Where a catalogue publishes only one interior width, the honest question to ask is whether the walls are tapered at all. We publish the narrow value where the moulding has one; on the 119 models where the field is empty we publish no narrow figure for that part number, and the right question is what that moulding does at its tightest section rather than assuming the nominal width holds all the way down.

## Driver five: hardware, wheels and telescopic handle height change the envelope, not the cavity

Handles, latches, hinge barrels, feet and padlock hasps are bolted or moulded onto the outside, so they grow the dimensions that freight and storage care about while leaving the interior untouched. Two published fields make this measurable. The first is wheels: 19 models in our catalogue carry them, and every one of those 19 is also marked not stackable, because a wheeled base with a recessed frame is not a stable column and the corner feet set the box off a flat deck. The second is the telescopic handle, published as a height on 11 models, from 240 to 485 mm. Add it to the external height and the carried envelope changes completely: KX-97227 goes from 270 mm of box to 755 mm of handle-up profile, and KX-88442 from 415 mm to 710 mm. Neither figure is a stacking figure, and neither is an interior figure; both are what clears a van door, a rack or an aircraft hold.

Sealing is the third hardware input that touches the dimensions. 124 models list a seal as available and record it as a compressible gasket in a continuous moulded channel, which is one of the constructions that the width allowance is paying for alongside the wall itself; on the remaining 31 models the file states that no seal is offered on the shell. Latch count is specified per configuration rather than fixed by the shell, and the published hardware note on all 155 models records the latch body as accepting a standard padlock, which is a dimensional fact about the hardware, not a security claim. When you ask a supplier to change a latch type or move a handle, you are changing the outside numbers you will be quoting freight against, so the drawing has to be re-issued with it.

## How much of the outside is not usable inside, in published litres

The three volume fields in our file tell the story in one comparison. Median internal volume across the 155 models is 17.5 litres against a median external volume of 24.4 litres, and the share of the external cube that is structure rather than space ranges from 13 per cent (KX-4616, 22.8 L inside 26.2 L) to 47 per cent (KX-82812, 3.5 L inside 6.6 L). The extremes of scale are equally real: the smallest published interior is 0.3 litres (KX-1204, 120×90×40 outside) and the largest is 139.5 litres (KX-88442, 843×592×415 outside). A buyer who sizes a shipment or a shelf by external litres and a payload by internal litres will get both right; a buyer who uses one of the two for both jobs will be wrong by up to nearly half the box.

There is a fourth volume most buyers never see, and it is the one the factory actually quotes: the carton. 58 models publish carton dimensions together with pieces per carton, and median utilisation of the carton cube by case external volume across those models is about 90.8 per cent. KX-2005 ships 40 pieces in a 410x360x495 carton; KX-3207 ships 24 pieces in a 645x530x430 carton. Our container figures for 20GP, 40GP and 40HQ are supplied with each quotation rather than published per model, because they depend on which part numbers share the load - so the useful thing to ask for is the carton line, not a generic container claim.

## Which dimension field answers which buyer question

Different decisions are driven by different fields, and half of all sizing arguments are really a mismatch between the question and the column used to answer it. The mapping below is the one we use internally when a quotation request arrives with a photo and a hope instead of a drawing.

| Buyer Question | Field To Read | Worked Example From Our File |
|---|---|---|
| Will the equipment physically fit? | Internal length and width, then narrowest internal width | KX-4616: 338 mm internal width, 302 mm at the tight point |
| Will it close over a mounted item? | Lid depth and base depth, not total internal height | KX-88442: lid 320 mm over base 44 mm |
| Will it go on the shelf or in the rack? | External length, width and height | KX-3218: 315×260×180 outside |
| What does the freight cost? | Carton dimensions and pieces per carton | KX-2005: 40 pcs in 410x360x495 |
| Can I stack it? | Stackable flag plus external footprint | 19 of 155 models marked not stackable, all of them wheeled |
| What height do I carry? | External height plus telescopic handle height | KX-97227: 270 mm box plus 485 mm handle |
| Is the interior safe for the item? | Foam layout and material option, per configuration | Pick-and-pluck, die-cut, CNC-cut, EVA, PE and EPE offered as options |

## What we do not state about dimensions, and why

Being precise about the limits of a datasheet is part of being precise about the datasheet. We publish measured values for internal and external dimensions, wall thickness, lid and base depth, narrowest internal width, telescopic handle height, net weight, and published interior and external litres, per model. We do not publish a dimensional tolerance band as a single blanket figure, because it is set by the moulding, the material and the part size, so it comes with the drawing for the part in question. We do not print a waterproof or dust code, a stack load or an impact grade: those protection fields are recorded as not measured in our product data, and an unmeasured field is left as not measured rather than filled with an estimate. If a project requires a named standard, we quote accredited third-party testing against it for the specific configuration, and the report belongs to that configuration.

The same discipline applies to the numbers on this page. Every figure quoted here is read from the published product file for the exact model named, and the counts - 148 models with a wall value, 100 with a lid and base split, 36 with a narrowest width, 11 with a telescopic handle, 58 with carton data - are counts of published rows, not claims about the range as a whole. Where a model lacks a field, that model has no published value for it. A supplier who quotes you a range-wide capability derived from one good part number is describing a brochure, not a catalogue; the test to apply on any inbound datasheet is whether the field exists for the part number you intend to buy.

## Sizing guidance: how to use these drivers when you shortlist

Start from the item, not the case. Record the equipment as it will actually be packed - connectors, cables, antennas, handles and any protective bumpers on - then add the allowance for the foam you intend to use. Take that as a minimum internal box, then read the internal line of a candidate model and, critically, the narrowest width if the item has square corners. Only then compare external dimensions, and compare them for the job they do: footprint for racking, total external height with the handle up for the vehicle, carton cube for freight. If a model fails the interior test but passes everything else, it is a foam problem, not a case problem, and foam is the cheapest thing on the order to change. If it fails the internal length or width, no amount of lining fixes it, and the right answer is a different footprint or a new tool.

Two shortcuts we will happily give away. First, work in families: if a footprint exists in three heights such as 315×260×70, 315×260×128 and 315×260×180 outside, you are choosing a depth, not a supplier. Second, when the equipment is irregular, ask for the lid and base split before you ask for the total, because an asymmetric cavity often fits an awkward item that a symmetric one of the same litres does not. For buyers who need an interior that the stock shells genuinely cannot give, our custom programme works from your drawing; new tools are a different commitment from a new insert, and the lead times below are the honest version of that difference.

## Applications where these drivers decide the choice

Electronics payloads are the most common case, because a rack box, a controller and a handset kit all want the same footprint and different depths; the interior and the narrow width decide the shortlist, and the electronics application page is where the family is grouped. Instrument and optical work adds the third constraint, since a bench instrument is often too tall for the base depth alone and has to be cradled across the parting line. Field and telecommunications deployments tend to be driven by the hardware fields: a wheeled shell that cannot be stacked changes how a whole kit is palletised, and a telescopic handle adds carried height that a vehicle load plan has to see. Ammunition and storage boxes are the opposite case, where the same footprint in several depths is bought deliberately so that a shelf line stays uniform while contents change.

Custom protective work sits across all of these, and it is where the five drivers become negotiable: wall thickness and material are selected for the load, the parting line can be re-set for a lidded assembly, the narrow width can be designed out of a new tool, and hardware can be moved to suit the packing position. What is not negotiable is the arithmetic - a bigger interior on the same outside always comes out of the wall, the rib or the rim, and one of those three has to give. A buyer who has that model in mind can have a productive conversation with any factory, including ours.

## Customising the dimensions: OEM, new tool and lead time

Our work is wholesale and OEM/ODM only, on EXW or FOB terms: we do not sell retail, do not quote DDP and do not hold overseas warehouse stock. For dimension changes, the practical ladder runs from cheapest to slowest: custom foam layout in an existing shell (pick-and-pluck, die-cut, CNC-cut, EVA, PE or EPE, as top, base or layered inserts) needs no tool change at all; colour, logo and print are configuration; hardware count and position are a configuration change on most part numbers; and only a change to the internal or external footprint itself requires a new tool. A first OEM sample on an existing tool is typically 45 days. A new mould is typically 125 days with a minimum order from 3,000 pieces per component. Payment is 30 per cent deposit with the balance after inspection, and third-party factory audits are welcome and are arranged against your inspector's protocol rather than ours.

If your request is really about interior geometry rather than a new shape, tell us the as-packed dimensions with the axes labelled, the item weight, the stacking or racking constraint, and the number of pieces you want per carton - the last one is the field buyers forget and the one that moves the freight price. Send it to Fred Zhao or the KeXin Sales Team, on WhatsApp +86 135 3588 0002, and the reply comes back as a drawing with the published fields filled in, not as a brochure page. KeXin New Materials (Guangdong) Co., Ltd. builds to the drawing you approve, and the acceptance criteria are the same fields listed on this page.

![Hard shell protective case with foam insert](https://kexincases.com/assets/img/pool/generic-case-25-900.webp)Hard shell protective case with foam insert

![Hard shell protective case with foam insert](https://kexincases.com/assets/img/pool/generic-case-90-900.webp)Hard shell protective case with foam insert

![Hard shell protective case with foam insert](https://kexincases.com/assets/img/pool/generic-case-04-900.webp)Hard shell protective case with foam insert

![Hard shell protective case with foam insert](https://kexincases.com/assets/img/pool/generic-case-16-900.webp)Hard shell protective case with foam insert

## Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

## Procurement considerations

| Question | What to send us |
|---|---|
| Which shell fits? | Equipment L × W × H as packed, plus required clearance per axis |
| What does it cost? | Order quantity and estimated annual quantity — the two drive different answers |
| Is tooling needed? | Whether an existing shell clears the envelope with usable foam depth |
| Lead time? | Your required delivery date, not just the order date |
| Certification? | The exact standard your tender names — we will say whether we can test to it |
| Freight? | Destination and preferred terms; carton and pallet data supplied with the quotation |

## Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

| Situation | What To Do |
|---|---|
| Fastest | Standard shell plus CNC foam — typically 45 days from approved drawing. |
| Branded | Standard shell plus custom colour and logo — MOQ applies to the resin colour. |
| Bespoke geometry | New mould — 125 days, MOQ from 3,000 units per component. |

- Size on internal dimensions plus clearance, never on a product name.
- Choose the carrying method before the shell: it changes the series, not just the price.
- Specify the interior last, and decide up front whether the end user will reconfigure it.

What affects protective case dimensions for a hard-shell equipment case? relates to Logistics & Packing Guide. Related families: Custom Protective Cases / Electronics Cases / Military Protective Cases / Instrument & Equipment Cases / Ammunition Storage & Transport Boxes / Equipment Transport Cases. Related sectors: field and industrial equipment. Continue in the Logistics & Packing Guide cluster.

Entity relationships

![Three closed cases of increasing size in a row with the same latch, hinge and handle layout repeated as the shell grows](https://kexincases.com/assets/img/ai/what-affects-protective-case-dimensions-for-a-hardshell-equipment-case-900.webp)Illustrative rendering Illustrative rendering of a typical configuration, not a photograph of the shipped item. Dimensions and materials on this page come from our published model data.

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

[Talk To The Manufacturer→](https://kexincases.com/request-a-quote/)[Find the Right Case](https://kexincases.com/find-your-case/)

Next step

Logistics & Packing Guide · Technical

## Frequently asked on this topic

What affects protective case dimensions for a hard-shell equipment case?Five construction inputs, in order: the tool family that fixes the footprint, the wall thickness run for that moulding, the parting line that splits internal height into lid depth and base depth, the draft and ribs that create a narrowest internal width below the nominal interior width, and the hardware that projects outside the shell. In our published file the wall ranges from 2 to 6 mm over 148 models, the external-to-internal allowance medians are 26, 57 and 15 mm on length, width and height, and the narrowest-width field is up to 37 mm tighter than the interior width.Do internal and external dimensions of a hard case differ by twice the wall thickness?No, and this is the most common arithmetic error. Twice the wall accounts for two opposite walls, but not for the ribs, the latch and hinge bosses on the width axis, the sealing flange, the gasket groove or the rim at the parting line. Measured across our 155 published models the external-minus-internal gap has a median of 26 mm on length, 57 mm on width and 15 mm on height, with a spread from 5 to 130 mm on length alone. KX-1204 on a 2.6 mm wall shows 5/12/8 mm; KX-97227 on the thickest wall in the file, 6 mm, shows 130/65/60 mm.Why does lid depth and base depth matter if I already know the internal height?Because internal height tells you the cavity exists while the split tells you whether your item can use it. On all 100 models in our file that publish both fields, internal height equals lid depth plus base depth exactly, but only 29 of the 100 split it evenly, and the ratio reaches 7.27273 to one on KX-88442, where a 320 mm lid sits over a 44 mm base. An item that stands taller than the base depth must be cradled across the parting line, which changes both the foam layout and where the gasket bears.What is the narrowest internal width and should I design to it?It is the tightest cross-section inside the shell, published separately from the nominal internal width because moulded walls carry draft and corners carry ribs. 36 of our 155 models publish it, the median shortfall below the nominal width is 25 mm and the largest is 37 mm - on the 4710/4713/4716 family the interior is 345 mm wide but only 308 mm at the narrow point. If your item has square corners and a rigid body, design to the narrow figure; a round or tapered item can ignore it.Does a telescopic handle height change the dimensions I ship against?It changes the carried and handled profile, not the box. 11 models publish a telescopic handle height from 240 to 485 mm, and adding it to the external height takes KX-97227 from 270 mm to 755 mm and KX-88442 from 415 mm to 710 mm. Freight is quoted against the collapsed carton cube rather than the handle-up profile, but a van, rack or hold clearance has to be checked with the handle extended. Note also that 19 models have wheels and all 19 of those are marked not stackable.How much of a case's external volume is lost to the shell?Between 13 and 47 per cent of external volume across our published models, with a median interior of 17.5 litres against a median exterior of 24.4 litres. KX-4616 keeps 22.8 L of 26.2 L, while KX-82812 keeps 3.5 L of 6.6 L because a deeper cavity in a short footprint spends more of its cube on walls and structure. Use the interior litre field for payload and the exterior or carton figure for space and freight, never one for both.Can you change the dimensions of an existing shell without a new mould?Within limits, yes, and the limits are the five drivers above. Interior geometry on an existing tool is changed with foam, not with the shell: pick-and-pluck, die-cut, CNC-cut, EVA, PE and EPE as top, base or layered inserts. Colour, logo, packaging and hardware configuration are options on existing part numbers. A first OEM sample on an existing tool is typically 45 days. A genuinely new footprint or a moved parting line is a new mould: typically 125 days, minimum order from 3,000 pieces per component, 30 per cent deposit and balance after inspection, EXW or FOB, wholesale and OEM/ODM only.

## Continue in Logistics & Packing Guide

Related

[TECHNICALInternal Versus External Dimensions](https://kexincases.com/knowledge-center/internal-vs-external-dimensions/)[TECHNICALHow To Measure Equipment For A Case](https://kexincases.com/knowledge-center/how-to-measure-equipment-for-a-case/)[PROCUREMENTContainer Loading For Protective Cases](https://kexincases.com/knowledge-center/container-loading-for-protective-cases/)[KNOWLEDGEHow To Read A Protective Case Datasheet](https://kexincases.com/knowledge-center/how-to-read-a-protective-case-datasheet/)[TECHNICALStacking and Palletising Protective Cases](https://kexincases.com/knowledge-center/stacking-and-palletising-protective-cases/)[KNOWLEDGEHow can protective cases improve equipment organization?](https://kexincases.com/knowledge-center/how-can-protective-cases-improve-equipment-organization/)[PROCUREMENTWhat Factors Affect Shipping Costs for Protective Cases?](https://kexincases.com/knowledge-center/what-factors-affect-shipping-costs-for-protective-cases/)[LOGISTICSHow Can Case Size Affect Logistics Efficiency?](https://kexincases.com/knowledge-center/how-can-case-size-affect-logistics-efficiency/)[LOGISTICSHow Should Equipment Cases Be Palletized? A Carton-First Method](https://kexincases.com/knowledge-center/how-should-equipment-cases-be-palletized/)[LOGISTICSWhat factors affect protective case selection for logistics?](https://kexincases.com/knowledge-center/what-factors-affect-protective-case-selection-for-logistics/)[COMPARISONHow Do Buyers Compare Protective Case Dimensions Across Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-protective-case-dimensions-across-protective-case-suppli/)[COMPARISONHow do buyers compare case weight across protective case suppliers?](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-weight-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Handles Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-handles-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Seals Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-seals-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Gaskets Across Protective Case Suppliers? The Bead, The Channel, The Closure](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-gaskets-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Hinges Across Protective Case Suppliers? A Field-by-Field Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-hinges-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Latches Across Protective Case Suppliers? A Closure-Geometry Method](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-latches-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Load Capacity Across Protective Case Suppliers? A Field-by-Field Audit](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-load-capacity-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Wheels Across Protective Case Suppliers? A Published-Field Audit](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-wheels-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Stackability Across Protective Case Suppliers? A Field-by-Field Guide](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-stackability-across-protective-case-suppliers/)[COMPARISONHow Do Buyers Compare Case Palletization Across Protective Case Suppliers? A Field-by-Field Guide](https://kexincases.com/knowledge-center/how-do-buyers-compare-case-palletization-across-protective-case-suppliers/)[TECHNICALHow Should Field Research Equipment Be Transported? A Packing Method From The Factory](https://kexincases.com/knowledge-center/how-should-field-research-equipment-be-transported/)[KNOWLEDGECommon Mistakes in Protective Case Dimensions for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-protective-case-dimensions-for-equipment-trans/)[COMPARISONWhat Affects Internal vs External Dimensions for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-internal-vs-external-dimensions-for-a-hardshell-equipment-case/)[KNOWLEDGECommon Mistakes in Internal vs External Dimensions for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-internal-vs-external-dimensions-for-equipment/)[TECHNICALWhat Affects Case Weight for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-case-weight-for-a-hardshell-equipment-case/)[PRODUCTWhat Affects Case Load Capacity for a Hard-Shell Equipment Case?](https://kexincases.com/knowledge-center/what-affects-case-load-capacity-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat Are The Common Mistakes In Case Load Capacity For Equipment Transport Cases?](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-load-capacity-for-equipment-transport-cas/)[PRODUCTWhat affects case wheels for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-wheels-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case wheels for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-wheels-for-equipment-transport-cases/)[PRODUCTWhat affects case handles for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-handles-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case handles for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-handles-for-equipment-transport-cases/)[KNOWLEDGEWhat are the common mistakes in case weight for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-weight-for-equipment-transport-cases/)[PRODUCTWhat affects case hinges for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-hinges-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case latches for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-latches-for-equipment-transport-cases/)[KNOWLEDGECommon Mistakes in Case Hinges for Equipment Transport Cases: An Eight-Point Field Guide](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-hinges-for-equipment-transport-cases/)[PRODUCTWhat Affects Case Latches for a Hard-Shell Equipment Case? Eight Published Factors](https://kexincases.com/knowledge-center/what-affects-case-latches-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case seals for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-seals-for-equipment-transport-cases/)[PRODUCTWhat affects case gaskets for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-gaskets-for-a-hardshell-equipment-case/)[PRODUCTWhat affects case stackability for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-stackability-for-a-hardshell-equipment-case/)[KNOWLEDGEWhat are the common mistakes in case stackability for equipment transport cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-stackability-for-equipment-transport-case/)[LOGISTICSWhat affects case palletization for a hard-shell equipment case](https://kexincases.com/knowledge-center/what-affects-case-palletization-for-a-hardshell-equipment-case/)[KNOWLEDGECommon Mistakes in Case Palletization for Equipment Transport Cases](https://kexincases.com/knowledge-center/what-are-the-common-mistakes-in-case-palletization-for-equipment-transport-cas/)[PROCUREMENTHow Should Protective Case Dimensions Be Specified In A Protective Case RFQ?](https://kexincases.com/knowledge-center/how-should-protective-case-dimensions-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat Information Should Be Provided About Protective Case Dimensions Before a Quotation?](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-protective-case-dimensions-before-a/)[PROCUREMENTHow Should Case Weight Be Specified In A Protective Case RFQ?](https://kexincases.com/knowledge-center/how-should-case-weight-be-specified-in-a-protective-case-rfq/)[PROCUREMENTHow should case load capacity be specified in a protective](https://kexincases.com/knowledge-center/how-should-case-load-capacity-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat information should be provided about case load](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-load-capacity-before-a-quotatio/)[KNOWLEDGEIndustrial Tool Transport Case: Sizes, Foam, Mobility](https://kexincases.com/knowledge-center/industrial-tool-transport-case/)[KNOWLEDGECold Chain Equipment Case: What a Shell Can Prove](https://kexincases.com/knowledge-center/cold-chain-equipment-case/)[KNOWLEDGEAutomotive Equipment Transport Packaging Solutions](https://kexincases.com/knowledge-center/automotive-equipment-transport-packaging-solutions/)[KNOWLEDGECommunication Equipment Transport Packaging Solutions](https://kexincases.com/knowledge-center/communication-equipment-transport-packaging-solutions/)[KNOWLEDGEDrone Equipment Transport Packaging](https://kexincases.com/knowledge-center/drone-equipment-transport-packaging/)[COMPARISONInternal vs External Dimensions Before a Quotation](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-internal-vs-external-dimensions-befo/)[PROCUREMENTSpecifying Case Wheels in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-wheels-be-specified-in-a-protective-case-rfq/)[KNOWLEDGEHow To Measure Usable Interior Dimensions](https://kexincases.com/knowledge-center/how-to-measure-usable-interior-dimensions/)[COMPARISONInternal vs External Dimensions in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-internal-vs-external-dimensions-be-specified-in-a-protective-case-r/)[PROCUREMENTWhat information should be provided about case hinges](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-hinges-before-a-quotation/)[PROCUREMENTHow should case latches be specified in a protective RFQ](https://kexincases.com/knowledge-center/how-should-case-latches-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to Send About Case Handles Before a Quotation](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-handles-before-a-quotation/)[PROCUREMENTHow to Specify Case Locks in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-locks-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to Provide About Case Wheels Before a Quote](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-wheels-before-a-quotation/)[PROCUREMENTHow to Specify Case Handles in a Protective Case RFQ](https://kexincases.com/knowledge-center/how-should-case-handles-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat information should be provided about case locks](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-locks-before-a-quotation/)[PROCUREMENTHow to specify case hinges in a protective case RFQ](https://kexincases.com/knowledge-center/how-should-case-hinges-be-specified-in-a-protective-case-rfq/)[PROCUREMENTWhat to provide about case latches before a quote](https://kexincases.com/knowledge-center/what-information-should-be-provided-about-case-latches-before-a-quotation/)[![Custom Protective Cases](https://kexincases.com/assets/img/app/foam-custom.webp)PRODUCT FAMILYCustom Protective Cases](https://kexincases.com/products/custom-protective-cases/)[![Electronics Cases](https://kexincases.com/assets/img/app/electronics.webp)PRODUCT FAMILYElectronics Cases](https://kexincases.com/products/electronics-cases/)[![Military Protective Cases](https://kexincases.com/assets/img/app/military.webp)PRODUCT FAMILYMilitary Protective Cases](https://kexincases.com/products/military-protective-cases/)