Procurement Guide · Technical

Protective Cases for Test, Measurement & Inspection Instruments for High-Precision Work

Quick answer

Short answer: choose the case from the instrument's packed envelope and its failure mode, not from a rating printed on a listing. Record the length, width and height of the device with its probe, cable and power supply, add the foam you intend to bury it in, then match that sum to the published internal cavity of one specific model. KeXin publishes internal and external dimensions and interior volumes for all 155 models, plus wall thickness, lid and base depth and net weight for most of them, recording a blank as not measured instead of guessing, so a metrology or quality buyer can shortlist on real numbers before asking a single commercial question. Sealing, anti-static behaviour and shock performance are configuration options you name on the order and then verify against an accredited-laboratory report for that exact build; we state no ingress protection code that we cannot trace to a test record for your configuration.

Key points

  • Measure the instrument with probe, cable and power supply, then add the foam depth; that sum is compared with the published internal cavity, not the outer box size.
  • Lid depth and base depth decide what you can actually pack: a 165/35 mm split suits a tall handheld with a stand, a 40/40 mm split suits a flat instrument tray.
  • Wall thickness is a published per-model figure in our range, from 2.0 mm on a light shell to 6.0 mm on a heavy engineering-PP box, and it changes handling stiffness.
  • A gasket is a closure option you order, so check seal availability per model; we do not print an ingress protection code without a test record for the build you buy.
  • Keep heavy steel gauges and reference standards in their own full-depth pockets so they cannot migrate into optics, lenses or sensor faces during transport.
  • OEM changes to foam, hardware and marking reach a first approved sample in about 45 days; changing the shell geometry means a new mould programme near 125 days.

Start from the packed envelope, not from the catalogue page

A high-precision instrument is rarely the size the datasheet advertises, because the packed envelope includes whatever you cannot leave behind: the probe lead coiled beside the body, the mains adapter, a reference block, a calibration certificate folder, the carrying strap. Write down the envelope as three numbers plus the mass, then decide how much foam each face needs. KeXin lists the internal cavity and the usable interior volume per model, so a buyer comparing a 240 by 200 by 120 mm cavity against a 253 by 180 by 152 mm cavity is comparing real space rather than a photograph. Two cases with the same footprint can differ by 40 mm of depth, and for an instrument with a raised lens or a protruding connector, those 40 mm decide whether the lid closes on the device or on the foam.

Medical DNA and gene analyser portable cases: what actually has to fit

A portable nucleic-acid or gene analysis unit is the awkward case in this category: a benchtop footprint, a lid that must not be loaded, and reagent consumables that must travel with it. Size the shell from the analyser body plus its power supply, then split the interior so the reagent strip or sample tray sits in its own pocket away from the instrument, because a spill must be containable without soaking the electronics. A deeper engineering-PP model such as KX-93221 gives a published internal cavity of 300 by 200 by 200 mm with a 165 mm lid and 35 mm base depth, 5.0 mm wall and 1230 g net, which suits an analyser with a fixed reader head. A lighter instrument travels better in KX-3218 at 308 by 230 by 172 mm internal, 900 g net, with an 86 mm and 86 mm lid and base split that lets the cavity open close to flat for loading.

Handheld medical analysers and the safety hard box

For a handheld clinical analyser - a haemoglobin, glucose, electrolyte or lactate reader with its test-strip cassette and charging cradle - the packing job is smaller but the failure mode is worse, because the optics at the strip slot are the first thing to take a point load. Choose a compact shell with a full-depth pocket around the body and a shallow relief over the strip window so no foam presses the aperture. Our small models cover this range honestly: KX-92817 gives 253 by 180 by 152 mm inside with a 5.0 mm engineering-PP wall at 940 g, while KX-83015 gives 245 by 190 by 140 mm in PP with a 3.7 mm wall and a gasket closure option. Ask for the cradle and cable in the same cut layout; a separate loose lead is the item that most often cracks a lens in a bag.

Portable hardness testers: mass, anvil and indenter protection

A portable hardness tester is a small machine, not a small meter. The body is heavy, the anvil and indenter are precision-ground, and the test block you carry for daily verification is steel. That means the interior needs a dense base layer and pockets that separate mass from optics. KX-3315 is a practical choice here: published internal dimensions of 303 by 224 by 135 mm, a 4.1 mm engineering-PP wall, 100 mm lid and 35 mm base depth, 1670 g net and 9.2 litres internal volume, which leaves room for the tester, anvil set and a reference block in separate wells. Where the kit includes a display unit and a coupling cable, KX-63619 in ABS gives 333 by 217 by 175 mm inside, 3.5 mm wall and 12.6 litres. The rule we apply in cut layouts: the indenter never shares a pocket with the reference block, and nothing sits directly under a latch.

The shockproof briefcase format for high-precision measuring tools

Buyers searching for a shockproof briefcase for precision measuring tools want a flat, hand-carried shell that opens on a bench and stays put. Briefcase format means shallow: total internal depth in the 80 to 100 mm region, an internal length long enough for a height gauge or a set of bore gauges, and a base that can carry steel without the foam taking a permanent set. KX-704 publishes 350 by 220 by 80 mm internal with a 40 mm and 40 mm lid and base split at only 630 g net and a 2.1 mm engineering-PP wall, which is the light option for gauge blocks and micrometers. KX-712 at 308 by 250 by 96 mm and 710 g gives a squarer footprint with a 54 mm lid, useful when the kit has a digital readout unit. Shock protection in either case comes from the foam layout you specify, not from the shell alone.

High-precision sensor trays: why lid depth beats internal height

A sensor tray loadout - transducers, accelerometer mounts, thermocouple heads, connector looms, spares - is a shallow, organised problem. What matters is not one big cavity but a 30 to 40 mm lid zone and a 30 mm base zone, so every item is visible and reachable without lifting the tray out. KX-3607 publishes 355 by 280 by 60 mm internal with a 30 mm and 30 mm split, 3.0 mm wall and 800 g net, and the same footprint is available at 70 mm and 80 mm depth as KX-3608 and KX-3609, which lets you buy the depth your tray really needs instead of the nearest box. KX-3508 moves to engineering PP at 344 by 268 by 72 mm and 995 g for trays that see a lot of handling. For trays we recommend a layered cut with a pick-and-pluck top layer, so a technician can re-tune the pocket when a sensor type changes.

High-altitude and elevation inspection meters: a portable box for the cold leg

Atmospheric, altitude and elevation inspection meters are used where the case is opened with gloves, on a windier surface, and often after a vehicle leg. Choose a shell that stays manageable in gloves - a handle you can grip fully, latches that release one-handed, and a body depth that lets the instrument lie flat rather than stand proud. KX-63413 gives a compact ABS format at 310 by 255 by 106 mm internal, a 4.8 mm wall and 1680 g net with a gasket closure option, which is the more rigid of the small shells we publish. KX-3114 in PP at 290 by 220 by 126 mm and 675 g is the lighter carry where the kit is a meter plus a probe. Cold affects batteries and displays, so we advise carrying the instrument at transport temperature and letting it settle before measurement; the case buys you the mechanical protection, not the thermal stabilisation.

Infrared thermometers, industrial and medical, in one small box

An industrial infrared thermometer for surface and process work, and a medical infrared thermometer for screening, are the same packing problem with different hygiene rules: a small pistol-grip or handheld body, a lens that must not be pressed, and a battery compartment that should stay reachable. For the industrial unit, KX-2614 publishes 240 by 200 by 120 mm internal with a 60 mm and 60 mm split at 460 g net and a 2.2 mm wall - a light PP shell for a spot pyrometer with a spare battery. KX-2813 steps up to engineering PP at 260 by 200 by 117 mm, 2.8 mm wall and 800 g, with a 92 mm lid that takes a laser-sighting accessory. For medical screening units, treat hygiene as the deciding factor: pick a model with a smooth base you can wipe down, keep the device in its own pocket, and specify a closure option you intend to have gasketed. Do not mix an industrial and a clinical thermometer in one tray.

NDT instruments and the waterproof request: what we will state and what we will not

Ultrasonic thickness gauges, flaw detectors, probes, wedges, couplant and reference blocks are the classic request in this group, and they usually arrive phrased as a search string asking for a waterproof NDT instrument case with an ingress protection code attached. We will not print an ingress code for a build we have not seen tested, and the models in our data sheet carry the same policy: the sealing entry is recorded as not measured, and the protection rating entry states that no code is stated and accredited testing can be commissioned per configuration. What we can specify mechanically is a continuous moulded channel with a compressible gasket and latch compression, available on models such as KX-63917 at 360 by 240 by 150 mm internal, 3.8 mm ABS wall and 1810 g net, or KX-64112 at 393 by 280 by 112 mm and 1820 g. If your tender needs a stated code, we quote the test as a separate work package and put the accredited report for your exact build into the file.

Laser distance meters: the case, and why pre-cut foam beats loose pluck

A laser distance meter travels in a pocket, a tool bag or a dashboard, which means it takes constant low-level abrasion and point loads rather than one dramatic impact. The lens and the reference edge on the base foot are what fail. For a single unit with charger and a small target plate, KX-83015 at 245 by 190 by 140 mm internal or KX-92817 at 253 by 180 by 152 mm is enough cavity, with a full-depth pocket holding the body and a shallow well for the strap. Where buyers ask for a pre-cut foam protective box rather than pick-and-pluck, we cut to your device: a pre-cut pocket locates the meter in one position, keeps the foot edge clear of foam pressure, and lets you check at a glance that a unit is missing. Pre-cut EVA or cross-linked PE is the right answer for a fleet of identical meters; pick-and-pluck suits a mixed kit that changes every quarter.

Comparison table: instrument family to the figure you should check

Read this table as a shortlisting method. Every number in it is the published specification of one named model, not a family average, so it is only useful when you compare it with your own measured envelope. If your packed instrument plus foam exceeds the internal length, width or depth of the row you are looking at, move up a model rather than reducing the foam to make it fit.

InstrumentWhat Must Stay ClearFigure To CheckPublished Example
Portable DNA or gene analyserReader head, reagent tray, mains adapterInternal height, lid and base split, net weightKX-93221: 300 x 200 x 200 mm, 165/35 mm lid/base, 5.0 mm wall, 1230 g
Handheld clinical analyserStrip slot optics and charging cradlePocket depth over the aperture, usable volumeKX-92817: 253 x 180 x 152 mm, 5.5 L usable, gasket option listed
Portable hardness testerIndenter, anvil, steel reference blockBase depth, wall thickness, mass supportKX-3315: 303 x 224 x 135 mm, 100/35 mm lid/base, 4.1 mm wall, 1670 g
Precision measuring tools in briefcase formatGauging faces and digital readout unitInternal depth and footprint, weight carried by handKX-704: 350 x 220 x 80 mm, 2.1 mm wall, 630 g; KX-712: 308 x 250 x 96 mm, 710 g
Sensor and transducer trayConnector bodies, cable looms, mountsLid and base depth split, same footprint in three depthsKX-3607 / 3608 / 3609: 355 x 280 mm at 60, 70 or 80 mm internal depth
High-altitude inspection meterSensor head, glove-operable latchesWall thickness, handle and latch option, massKX-63413: 310 x 255 x 106 mm, 4.8 mm wall, 1680 g, gasket option listed
Infrared thermometer, industrial or medicalOptics and battery compartmentSmall cavity volume, wipe-clean baseKX-2614: 240 x 200 x 120 mm, 460 g; KX-2813: 260 x 200 x 117 mm, 800 g
NDT gauge with probes and wedgesProbe crystal, wedge faces, couplant bottleInternal length and depth, closure option, seal availabilityKX-63917: 360 x 240 x 150 mm, 3.8 mm ABS, 13.0 L internal, seal available
Laser distance meter fleetLens, base foot edgePocket layout, pre-cut versus pick-and-pluckKX-83015: 245 x 190 x 140 mm, 3.7 mm wall, 6.5 L internal

Selection guidance: three checks before you commit to a model

First check fit in three axes with the closure allowance: subtract nothing from the internal figure, but add 5 mm to each side of the instrument for the pocket wall and the tolerance of the cut. Second check the handling path: an instrument that is carried up a ladder needs mass in the shell, so our lighter 2.0 to 2.2 mm wall models trade stiffness for weight, while a 3.8 to 5.0 mm wall suits a case that will be loaded into a vehicle repeatedly. Third check the logistics figure: the carton size and pieces-per-carton we publish decide your landed cube, and on a fleet order that is often the difference between a viable and an unviable quote. KX-2813 ships 20 pieces per carton at 560 by 490 by 665 mm; KX-63917 ships 8 pieces per carton at 625 by 405 by 717 mm. Same category, very different freight.

Applications: field metrology, laboratory transfer, and production inspection

Three use patterns drive most of the instrument orders we quote. Field metrology and calibration visits need one case per instrument plus its reference standards, hand-carried, so briefcase and small hard-shell formats dominate. Laboratory transfer - moving a sample handler, an analyser or a sensor rig between rooms or buildings - favours tray-style shallow boxes where everything is visible and nothing has to be re-packed. Production inspection at a machine side is the harshest: vibration, coolant, and a case opened on a metal surface, so thicker walls and a gasket closure option are usual, and we cut the foam so the instrument can be lifted out without the lid dragging the accessories. Tell us which of the three you are buying for, because the same instrument can justify three different cases.

Customising the interior: cut foam, layering, and control marking

The interior is where the protection actually lives, and it is the fast path. Send a drawing, a photograph of the packed kit, or the physical instrument, and we cut pockets to it in cross-linked PE, EVA or EPS by zone, with optional layered and pick-and-pluck top layers so a lab can re-tune a pocket without a new tool. We can also mark the interior and exterior for configuration control: instrument serial number, calibration due date holder, a document pocket for the certificate, or a colour-coded foam zone so the right meter leaves the right shelf. Custom logo and colour run from 300 units; custom foam is quoted from one. An OEM change to foam and hardware on an approved shell reaches a first sample in about 45 days; only a new shell geometry needs a mould programme near 125 days.

Procurement notes: terms, verification and what to put on the purchase order

KeXin manufactures these shells and sells wholesale, OEM and ODM only, on EXW or FOB terms. We do not retail, do not quote DDP and hold no overseas stock warehouse, so price your landed cost from the FOB figure and your own forwarder. Standard shells are quoted from one unit; logo, colour and OEM hardware run from 300, and a custom mould from 3,000 per component. Payment is a 30 percent deposit with the balance after inspection, and third-party factory checks are welcome. On the purchase order, write the configuration rather than a hope: model, internal figure you measured, foam layout reference, closure option, colour, marking, and any performance figure you need proven, with the accredited report for that build named as a deliverable. Where a number is not in our published per-model data, we record it as not measured instead of guessing.

Transport protection for measuring instruments: the three legs of the journey

Transport protection for measuring instruments is a sequence, not a single event, and it is worth designing for each leg. The hand-carry leg produces knocks to the corners and lid edge, which is why we recommend foam that stands proud of the instrument on every face and a rim that keeps the lid off the ground. The vehicle leg produces sustained vibration and sliding, so the pocket must locate the body firmly and accessories must not rattle against a steel reference block. The freight leg produces stacking and impact from other cargo, so the carton figure and pieces-per-carton we publish matter as much as the case itself. A case that survives all three legs is one specified for all three; a case chosen for the photograph usually fails on the second.

Bridge inspection instrument case: what we publish and what we leave as a test

A bridge inspection instrument case is usually specified the wrong way round, so this section answers the phrase as buyers type it. A deck or underside kit carries crack-width and coating-thickness gauges, a concrete cover meter, probes, wedges and a reference block, and the things that decide the model are the internal length, width and depth of your measured packed envelope, the narrow internal width that binds a rigid tray, the lid-to-base split that clears a raised connector, and the loaded mass someone lifts on rope access.

We publish every one of those figures per named model. We do not print an ingress code, an IP rating or any waterproof figure for these shells; on our data sheet the sealing entry is recorded as not measured, so a water or dust level is a test we commission on the exact ordered configuration and hand back as an accredited report, not a number written into the listing to fill a cell.

Search PhraseFigure That Decides ItPublished Example
bridge inspection instrument caseMeasured internal envelope, narrow internal width, lid-to-base split and loaded mass decide the fit; a compressible gasket in a moulded channel is a construction you can inspect, while the ingress level is recorded as not measured and is tested per configuration on request.KX-63917: 360 x 240 x 150 mm internal, ABS shell, 3.8 mm wall, about 1,810 g net, 13.0 L internal, gasket in a moulded channel, no ingress code published
rugged gauge box for field and elevated inspectionGlove-operable closure, wall thickness and the mass carried up a ladder decide this more than a rating word, so we publish wall, net mass and the handle option and leave the water level blank until it is actually tested.KX-63413: 310 x 255 x 106 mm internal, ABS shell, 4.8 mm wall, about 1,680 g net, 8.4 L internal, gasket option listed, ingress not measured

How to read the empty protection cell on a bridge inspection kit

Treat the blank protection cell as information rather than a gap. A continuous moulded channel with a compressible gasket and a stated latch count tells you the rim can be checked on the drawing and on a sample, and on a field instrument that is often the whole requirement; it does not assert that a laboratory test was passed, and we are not going to imply one. If your inspection method or tender names a specific ingress level, put that level on the purchase order as a performance figure to be proven, and we quote accredited third-party testing of your nominated model and configuration as a separate work package. Everything you can shortlist from a catalogue sits on the left of that line, in published millimetres, grams and wall thickness per SKU.

Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case

Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

Procurement considerations

QuestionWhat to send us
Which shell fits?Equipment L × W × H as packed, plus required clearance per axis
What does it cost?Order quantity and estimated annual quantity — the two drive different answers
Is tooling needed?Whether an existing shell clears the envelope with usable foam depth
Lead time?Your required delivery date, not just the order date
Certification?The exact standard your tender names — we will say whether we can test to it
Freight?Destination and preferred terms; carton and pallet data supplied with the quotation

Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

SituationWhat To Do
Benchtop massFirm base carrier, 50 mm minimum, with a soft contact layer.
Optical headSuspend the body and clear the lenses entirely; never let foam touch a coated surface under load.
Field kitCNC base for the instrument, pluck-foam top for probes and consumables.
  • Size on internal dimensions plus clearance, never on a product name.
  • Choose the carrying method before the shell: it changes the series, not just the price.
  • Specify the interior last, and decide up front whether the end user will reconfigure it.
Entity relationships

Protective Cases for Test, Measurement & Inspection Instruments for High-Precision Work relates to Procurement Guide. Related families: Instrument & Equipment Cases / Electronics Cases / Medical Equipment Cases / Tool Cases. Related sectors: field and industrial equipment. Continue in the Procurement Guide cluster.

Next step

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

Talk To The Manufacturer→Find the Right Case

FAQ

Frequently asked on this topic

Which case fits test, measurement and inspection instruments for high-precision work?

Pick by packed envelope and failure mode. A handheld analyser or laser distance meter sits in a small shell such as KX-92817 at 253 by 180 by 152 mm internal; a benchtop analyser needs depth like KX-93221 at 300 by 200 by 200 mm; a hardness tester wants a thick base and separate pockets, so KX-3315 with its 4.1 mm wall; a gauge set travels in a shallow briefcase format such as KX-704. Confirm your own measured size against the published internal figure before anything else.

What internal dimensions do buyers of high-precision instrument cases need to check?

Three numbers plus the split. Take the internal length, width and depth of the model, then read the lid depth and base depth separately: a 30 and 30 mm split behaves very differently from a 165 and 35 mm split even at the same total depth. Add the pocket wall allowance and the foam thickness you intend to bury the device in, and check the usable interior volume we publish as well as the raw cavity, because wall and hardware steal space.

Can the foam insert be custom cut for analysers, gauges, probes and trays?

Yes, and this is the usual route. Send a drawing, a photo of the packed kit or the physical instrument, and we cut pockets in PE, EVA or EPS by zone, with layered or pick-and-pluck top layers so the layout can be re-tuned later. Custom foam is quoted from one unit. Marking for configuration control, such as serial number labels or a calibration-date document pocket, is added at the same time.

What MOQ and lead time apply to this category?

Standard shells are quoted from one unit; custom foam from one; logo, colour and OEM hardware from 300; a new mould from 3,000 per component. An OEM first sample on an approved shell takes about 45 days and a new mould about 125 days. We work wholesale and OEM or ODM only, on EXW or FOB terms, with a 30 percent deposit and balance after inspection, and third-party factory checks are welcome. There is no retail, no DDP and no overseas stock.

Which shell material and sealing suit high-precision instruments in the field?

PP covers light hand-carry work, engineering PP adds stiffness at similar weight, and ABS shells give a rigid, higher-mass body for harsh handling. Our published wall thickness ranges from 2.0 mm to 6.0 mm per model, so compare the specific figures rather than the material name. Sealing is a closure option: check whether the model lists a gasket channel as available, then have the exact build tested by an accredited laboratory if your tender needs an ingress figure, since we state no code without that record.

How do I stop a steel reference block damaging the instrument inside the case?

Separate the masses. Put the reference block, gauges and anvils in their own full-depth pockets in a denser base layer, so they cannot migrate during the vehicle leg, and never let a steel edge sit under a latch or directly beneath the instrument body. Where a kit mixes both electronics and gauge blocks, we usually split the cavity with a moulded or layered foam wall rather than relying on two adjacent pockets.

Related

Continue in Procurement Guide

PROCUREMENT

Protective Case Procurement Checklist

PROCUREMENT

MOQ, Tooling And Unit Cost: How They Interact

PROCUREMENT

Protective Case Factory Versus Trading Company

PROCUREMENT

OEM vs ODM vs Private Label Protective Cases

PROCUREMENT

What Information Should a Buyer Provide When Requesting a Protective Case Quotation?

PROCUREMENT

What Should International Buyers Ask a Protective Case Manufacturer?

OEM

Can Defense Equipment Cases Be Customized? What Changes and What Needs a New Tool

PROCUREMENT

How should international buyers evaluate a protective box supplier?

COMMERCIAL

Cases for Test & Measurement Instrument & Fors

COMMERCIAL

Cases for Hand Tools, Power Tools & Hardware in Factory Maintenance

TECHNICAL

Protective Cases for Machinery, Moulds & Spare Parts for Automation Lines

COMMERCIAL

Protective Cases for Machinery, Moulds & Spare Parts

COMMERCIAL

Cases for Robot End Effectors, Controllers & Spare Parts

COMMERCIAL

Cases for Sensor & Probe Test Instruments

OEM

Can Camping Equipment Cases Be Customized? What A Manufacturer Can Actually Change

COMPARISON

How do buyers compare internal vs external dimensions across protective case suppliers?

COMPARISON

How Do Buyers Compare Case Locks Across Protective Case Suppliers? A Closure-Field Method

PROCUREMENT

How should buyers choose an outdoor case?

OEM

Can Photography Cases Be Customized? Stock, Modified And Full OEM Compared

KNOWLEDGE

What are the common mistakes in case locks for equipment transport cases

PROCUREMENT

What Information Should Be Provided About Case Weight Before A Quotation?

KNOWLEDGE

Battery Module Tester Explosion-Proof Safety Box

KNOWLEDGE

Industrial Pressure Test Pump Matching Box

KNOWLEDGE

Explosion Proof Hard Safety Box Export Factory

Instrument & Equipment Cases
PRODUCT FAMILY

Instrument & Equipment Cases

Electronics Cases
PRODUCT FAMILY

Electronics Cases

Medical Equipment Cases
PRODUCT FAMILY

Medical Equipment Cases