Waterproof & Dustproof Guide · Procurement

Why should buyers ask manufacturers about testing methods?

Quick answer

Because the same sentence on a datasheet can rest on four completely different things, and only one of them is a test result. A number can be a production measurement taken from the part itself, an in-line check of how a feature was assembled, a value inferred from the material chosen, or a figure produced by a laboratory on a specific configuration. Those answer different questions, they expire in different ways and only the last one can be handed to a specification owner as evidence. Ask about the method and you find out which of the four you are buying. Our own catalogue is a worked example of why this matters: external and internal dimensions and volumes are published for all 155 models and wall thickness for 148, because they are recorded from production data; the sealing feature is published on 124 models as a gasket in a continuous moulded channel and on 31 as not offered; and dust, water, protection rating, stack load, load capacity, temperature range and UV are recorded as unmeasured on all 155, because no test record exists for those models and configurations. Where a documented result is required, we commission it against the exact model and configuration through an accredited laboratory as a separate work package, and the report belongs to the customer.

Key points

  • Ask who produced the number, on what apparatus, on which configuration, how many samples, with what pass criterion and when — six questions that sort most claims in five minutes.
  • Separate three states in any datasheet: measured from production, dependent on the configuration you order, and not established at all.
  • In our 155-model catalogue, seven protection fields are recorded as unmeasured on every model, so a rating has to be commissioned rather than read off.
  • A configuration option is not a test result: our impact entry publishes a wall thickness per model and states that no drop height is claimed without a test.
  • Check that the row you intend to rely on is actually filled in: 148 of our 155 models publish a wall figure, 93 a net weight, 58 a pieces-per-carton figure and none publishes a gross weight.
  • Test the configuration you will receive. Latch count, gasket compound, valve and foam layout are set at order stage, so a report generated on a different build proves little.
  • Put the method question in the request for quotation, not after delivery: cost and duration are quoted before a test starts, and report ownership is agreed at the same time.

A number is not evidence until you know how it was made

Protection claims are usually read as either present or absent: a case either has documented drop-test results or it has none, sealed or not sealed, rated or not rated. In procurement that binary is worthless, because what you actually need to know is what produced the figure and what it therefore covers. A wall thickness of 5.0 mm is a measurement of the part. A statement that the gasket is fully seated in a continuous channel is an assembly check. A note that the shell is thermoplastic with no ferrous corrosion path is a property of the material you chose. A peak acceleration figure from a dummy mass dropped in a defined orientation is a test result on one configuration. The first three are useful and honest; the fourth is the only one a specification owner can sign off against, and it is the one most often implied by marketing language that borrows the shape of a number.

Six questions sort almost every claim you will meet. Who ran it: the manufacturer's own floor, an accredited laboratory, or an internal opinion. On what: the exact model and the exact configuration, or a sister shell with a different wall, latch count or foam. With what apparatus and what pass criterion: what was measured, what counted as failure, and what was ignored. On how many samples: one unit tells you about that unit. When: an old report may predate a material or tooling change. And who holds the record: if the supplier keeps the report and you cannot cite it, its value to your programme is limited.

The three states a specification field can be in

We publish our own catalogue in three explicit states, and it is worth reading them as a template for how you should ask any supplier to present theirs. Measured means recorded from our own production or incoming-material data — the dimension and construction facts on the model page. Manufacturer option means a construction option we can supply where the figure depends on the configuration you order — gasket compound, pressure equalisation valve, latch count, foam material and layout, hardware metal or polymer, and the impact entry itself. Not measured means no test record exists for that model and configuration, we will not state a value, and accredited testing can be commissioned as a separate work package.

The distribution of those states across our 155 models is instructive, because it is the honest shape of what a case factory can actually say. Dimensions, internal and usable volume and shell material are measured and published on every model. Net weight is published on 93 models and lid depth on 100; gross weight is published on none, and a telescopic height appears on 11 of the 19 rolling models. The sealing feature is stated on 124 models as a compressible gasket in a continuous moulded channel and on 31 as not offered on that shell. Corrosion resistance is stated on all 155, but as a material construction fact — a thermoplastic shell with no ferrous corrosion path — not as a salt-spray result. Then come the seven fields that are unmeasured on every model: dust resistance, waterproofing, protection rating, stack load, load capacity, temperature range and UV resistance. That is not an oversight in our data; it is a statement that we do not have those records and will not print a number we cannot produce.

What changes once the method is known

Knowing the method changes three practical things: what the figure covers, how long it stays valid, and who can rely on it. A production measurement covers every unit that leaves the mould and is verifiable on the part with a calliper, so it belongs in your drawing and survives a supplier audit. An in-line assembly check covers the build you happened to inspect, which is why our sealing verification is written as conditions rather than as a number — gasket fully seated in a continuous channel with no twist, closure uniform across every latch checked by feel and by gap gauge, and no channel contamination from trim or adhesive. A material statement covers everything made from that resin lot and nothing else, which is why incoming-material records, certificates of analysis and lot traceability are the relevant documents rather than a test report. A laboratory result covers one configuration at one point in time, which is why the report has to name the build.

It also changes the cost conversation. A measurement is free because you are already paying for production control. A commissioned test is a work package with a price and a duration quoted before it starts, and the sensible sequence is to freeze the configuration first, then test. If you order testing before the latch count, gasket compound, valve and foam layout are settled, you pay twice and the first report is decorative. This is the specific reason the method question belongs to the buyer rather than to the supplier's marketing department: only you know which configuration the programme will actually receive.

What our published data puts in each state

Field On The Model PageState In Our CatalogueWhat A Buyer Can Rely On It For
External and internal dimensions, volumesPublished for all 155 models, from production dataFit checks against your equipment drawing, with foam clearance allowed on every face
Wall thickness; lid and base depth148 models publish a wall figure; 100 publish lid and base depthRim stiffness behind a closure and cavity depth, per model rather than across the range
Net weight; pieces per carton93 models publish net weight; 58 publish pieces per carton; none publishes gross weightHandling and freight estimates once you have confirmed the packing for your order
Sealing feature124 models record a gasket in a continuous moulded channel; 31 record none offeredClosure construction, not an ingress result — no rating is stated on any model
Corrosion resistanceAll 155, stated as a thermoplastic shell with no ferrous corrosion pathA material route removed from your failure list, not a salt-spray exposure figure
Impact and shock entriesRecorded as configuration options; each note cites the model wall and states no drop height is claimed without a testChoosing shell and foam, then commissioning a test if a figure is required
Dust, water, rating, stack load, load capacity, temperature, UVRecorded as unmeasured on all 155 modelsNothing yet — this is the work package you commission on a frozen configuration
Pallet quantity and container loadingCalculated from your carton footprint against your pallet; container figures come with the quotationFreight planning arithmetic rather than a stated capacity claim

The row you cannot use: an example from our own catalogue

Blank and half-filled rows are the most common way a buyer gets hurt, and they are the easiest to prevent by asking a method question early. Our own impact entry is a clean illustration. On every model it reads as a construction note quoting the wall thickness — for example that a 5.0 mm wall carries no drop height claim without a test — and on seven models it prints as a note with the wall value left empty, because those seven shells publish no wall figure at all. Those seven are the unsealed bodies in the 8, 9 and T series, including KX-84814, KX-84823, KX-95419, KX-6922 and the rolling KX-5126. If you were filling a compliance sheet from that row, you would have nothing to write, and the reason is not that the shell is bad: it is that a note designed to point at a measurement has no measurement behind it on that part.

The same pattern appears elsewhere in the range. Nineteen models publish a telescopic handle and two wheels, but only eleven publish the extended height, so the ergonomics argument is complete for some trolleys and open for others. Gross weight is published on none, which matters because the number a freight forwarder bills on is the packed weight, and that depends on the packing for your order rather than on the shell. Four models have no image in the catalogue. None of these gaps disqualifies a purchase, but each one is a question you should ask before a purchase order rather than after a delivery, because a supplier who states the gap is telling you the truth about the data and a supplier who papers over it is telling you something else.

Selection guidance: which method question to ask for which claim

For an ingress claim, ask whether the statement is about construction or about water. Construction you can verify from the model page and from the closure conditions checked on the floor: gasket compound, channel continuity, latch count and rim condition. Water behaviour needs a test on the exact build — spray, immersion or pressure-decay through an accredited laboratory — and a report that names that build. If a supplier answers a waterproof question by describing a gasket, that is a useful answer, but it is a different answer. Our policy on this point is set out on the quality pages: only tests actually performed are described with figures, and where no test record exists for a model we say so and quote the test as a separate work package.

For an impact or drop claim, ask what was instrumented and what counted as pass. Our impact page describes peak acceleration transmitted to a dummy mass in the carrier, whether the closure stayed closed, whether the shell recovered its shape or took a permanent set, and whether the foam crept under repeated events. That is a specification of a method, and it tells you which of those four your equipment actually cares about — an instrument with a calibration certificate usually cares about transmitted acceleration, a hinged box with a document pocket usually cares about the closure staying shut. For a drop duty, ask which orientations: corner, edge, face flat and top-down load completely different parts of the assembly, and our drop page notes that moving from a 20 mm to a 50 mm base layer under a 15 kg assembly is the single largest reduction available in a case of this type, and it costs foam rather than tooling.

For stack, load and freight claims, ask whether the figure is a measured capacity or arithmetic. We publish pallet quantity as calculated from the carton footprint against your pallet size, and container loading for 20GP, 40GP and 40HQ with the quotation, which is the honest way to give a planning number without claiming a load rating. For temperature and UV, ask whether anything was ever run at all; in our catalogue the temperature range and UV entries are unmeasured on all 155 models, and the relevant real control is resin selection, lot traceability and incoming-material records. For materials, ask for the certificate of analysis for the resin lot rather than a generic statement about plastic.

Where the method question decides the purchase

Instruments, metrology and laboratory equipment moved between sites are the clearest case, because there the case is protecting a certificate rather than an enclosure. Reference surfaces, accuracy claims and calibration intervals are all statements about cleanliness and temperature, so the buyer needs to know what evidence exists on the closure and what does not, and needs it before the unit is placed in service. Survey optics, thermal monoculars and camera bodies behave the same way, where a single grain on a lens is a rejected image and the honest specification is a defined closure with a cleanable channel rather than an ingress number.

Tendered defence, public-safety and infrastructure programmes are the second case, and here the method question is usually asked by someone else on your behalf: a technical compliance reviewer who will read a claim and demand the record behind it. If you have bought on a description, you either commission testing late and at a premium or you restate your offer. Medical and veterinary device programmes have the same exposure in a different form, because the interior layout, the cleaning regime and the security of the contents are what a reviewer will ask about, not a generic shell rating. Drone, payload and industrial site programmes differ mainly in that the drop duty is real and repeated, so the transmission question — what the content actually sees — is worth paying for on your own configuration.

For any of these, the practical route with a wholesale and OEM supplier is to buy construction you can verify from published geometry, then commission only the one or two documented results your programme genuinely needs. That is usually far cheaper than buying a catalogue full of unverified ratings, and it produces a report you own.

Fitting a test programme inside an OEM clock

Sequence is the part most buyers get wrong. On an existing mould, a first article takes 45 days; a new mould takes 125 days, with a minimum order from 3,000 per component and a 30 percent deposit. Logo, colour and OEM work starts at 300 units, while a standard shell or a custom foam insert can be ordered from one. Testing does not run in parallel with an open configuration, because the configuration is what the report names. So the workable order of events is: freeze the shell, latch count, gasket compound, valve decision and foam layout; confirm the first article; then commission the test on units from that build, with cost and duration quoted before it starts and with report ownership agreed in writing at the same time as the scope.

That sequence also protects you against the quiet failure mode in long programmes: a tooling, resin or hardware change that silently invalidates a report you have been citing for two years. Ask for the record to name the configuration and the production window, and put a change-control clause in the agreement so that a changed parting line, a new latch position or a different gasket compound triggers a notification rather than a surprise. Commercially we work wholesale and OEM only, on EXW or FOB terms, with no retail, no delivery-duty-paid service and no overseas stock — which is another reason a documented configuration record matters: the build you test is the build that ships.

Procurement notes: writing the method into your request for quotation

Put the requirement in the request for quotation rather than in a follow-up email. Ask for each figure you intend to rely on to be labelled as a production measurement, a configuration-dependent option or a test result; ask for the standard of evidence behind any test result, including the report holder; ask for the model page dimensions and closure statement, the latch positions and the foam drawing; and ask what is not available. A supplier who can answer in those three states is easy to compare against another supplier, and comparability is where most of the saving actually is. A supplier who answers with a single reassuring sentence is not comparable at all, whatever that sentence contains.

Then keep the distinction visible in your own documents. Write your internal specification so that geometry and construction sit in one column and evidenced performance sits in another, with the second column empty until a report exists. It sounds bureaucratic and it prevents the two most expensive arguments in this category: buying a construction feature as though it were a rating, and discovering at acceptance that the figure relied on was arithmetic. Our position on both is on the record in the catalogue itself: 124 models state a gasketed closure and 31 state that none is offered, seven performance fields state no record, and accredited testing is quoted as a separate work package on the exact configuration you order.

Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments
Protective case carrying measurement and test instruments

Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

Procurement considerations

QuestionWhat to send us
Which shell fits?Equipment L × W × H as packed, plus required clearance per axis
What does it cost?Order quantity and estimated annual quantity — the two drive different answers
Is tooling needed?Whether an existing shell clears the envelope with usable foam depth
Lead time?Your required delivery date, not just the order date
Certification?The exact standard your tender names — we will say whether we can test to it
Freight?Destination and preferred terms; carton and pallet data supplied with the quotation

Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

SituationWhat To Do
Occasional splashA close-fitting rim without a gasket is cheaper and easier to maintain.
Rain and washdownSealed configuration, four or more latches, stainless hardware.
Immersion or pressure changeSealed configuration plus a pressure-equalisation valve, and a documented test.
  • Size on internal dimensions plus clearance, never on a product name.
  • Choose the carrying method before the shell: it changes the series, not just the price.
  • Specify the interior last, and decide up front whether the end user will reconfigure it.
Entity relationships

Why should buyers ask manufacturers about testing methods? relates to Waterproof & Dustproof Guide. Related families: Waterproof Cases / Instrument & Equipment Cases / Electronics Cases / Military Protective Cases / Medical Equipment Cases / Drone & UAV Cases / Outdoor Protective Cases / Custom Protective Cases / Rolling Cases / Equipment Transport Cases. Related sectors: field and industrial equipment. Continue in the Waterproof & Dustproof Guide cluster.

Next step

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

Talk To The Manufacturer→Find the Right Case

FAQ

Frequently asked on this topic

Why should buyers ask manufacturers about testing methods?

Because a figure without a method does not tell you what it covers. The same sentence can rest on a production measurement from the part, an in-line assembly check, a property of the selected material, or a laboratory result on one configuration — and only the last is evidence a specification owner can rely on. Asking who ran it, on what build, with what apparatus and pass criterion, on how many samples, when, and who holds the report tells you within minutes which of the four you are being offered, and how much of your programme risk that figure actually retires.

What is the difference between a measured specification and a tested rating?

A measured specification is recorded from production or incoming-material data and can be verified on the part; our catalogue publishes dimensions and volumes on all 155 models, wall thickness on 148, lid depth on 100 and net weight on 93 that way. A tested rating is produced by a laboratory on a defined configuration and sample, and it expires if the build changes. In our range no ingress, drop, stack, temperature or UV rating is published on any model, because those records do not exist — a documented result is commissioned per configuration as a separate work package instead.

What questions should I ask before relying on a waterproof or dust claim?

Ask whether the statement is about construction or about water. Construction is verifiable: gasket compound, channel continuity, latch count, rim condition — and it is what our pages publish, 124 models with a compressible gasket in a continuous moulded channel and 31 stating none is offered. Water behaviour needs a test on the exact build, so ask which method was used, whether it was spray, immersion or pressure-decay, who ran it, whether the tested unit matches the configuration you will receive, and who holds the report. If the answer describes only the gasket, it is a useful answer to a different question.

Is it worth paying for a drop test on my own configuration?

Only when the programme genuinely needs the record, which usually means a tender reviewer, a warranty exposure or a repeated field drop duty. Ask first what the test would measure — in our case peak acceleration transmitted to a dummy mass, whether the closure stayed closed, whether the shell took a permanent set, and whether the foam crept under repeat events — and which orientations: corner loads the shell, edge loads the latch, face flat loads the base foam. Often the cheaper answer is a thicker base layer, since going from a 20 mm to a 50 mm layer under a 15 kg assembly is the largest reduction available in a case of this type and costs foam rather than tooling.

How do I compare two suppliers whose datasheets both look complete?

Ask each one to label every figure as a production measurement, a configuration-dependent option or a test result, and to state what is not available. Then check completeness rather than wording: in our own catalogue gross weight is published on no model, a telescopic height on 11 of the 19 rolling models and a wall figure on 148 of 155, with the impact note on the seven shells without a wall value reading as an empty measurement. A supplier who states those gaps plainly is comparable; a supplier whose sheet is uniformly reassuring is not.

Can you arrange accredited testing for the cases we order?

Yes, as a separate work package on the exact model and configuration, quoted for cost and duration before anything starts, with the report belonging to the customer. Order matters, because the report names the build: freeze the shell, wall, latch count, gasket compound, pressure equalisation valve decision and foam layout, confirm the first article, then commission the test. This sits inside our usual OEM frame — 45 days for a first article on an existing mould, 125 days for a new mould from 3,000 per component, 300 units for logo, colour or OEM work, EXW or FOB terms, wholesale and OEM only.

Related

Continue in Waterproof & Dustproof Guide

TECHNICAL

How Waterproof Cases Actually Work

KNOWLEDGE

What An IP Rating Does Not Tell You

TECHNICAL

Pressure Equalisation Valves Explained

TECHNICAL

What environmental factors should be considered for electronic equipment transport?

TECHNICAL

How Do Field Cases Protect Equipment From Dust And Moisture?

KNOWLEDGE

What Is Impact Testing?

KNOWLEDGE

What Is a Waterproof Protective Case?

KNOWLEDGE

What Is a Shockproof Protective Case?

KNOWLEDGE

What Is Waterproof Testing?

KNOWLEDGE

What Is a Dustproof Equipment Case? The Closure That Keeps Grit Out

KNOWLEDGE

What Is Drop Testing? The Procedure, What It Measures and What We Publish

TECHNICAL

How Do Outdoor Cases Protect Equipment From Environmental Conditions?

TECHNICAL

Why Is Waterproof Protection Useful for Outdoor Equipment? The Damage Water Does Before You Notice

TECHNICAL

Why Is Dust Protection Important For Electronic Equipment?

PROCUREMENT

How Should Buyers Select A Dust-Resistant Protective Case?

PROCUREMENT

What Combination Of Protection Features Should Buyers Consider?

PRODUCT

What Environmental Protection Should Field Equipment Cases Provide?

TECHNICAL

How Should Waterproof Case Seals Be Maintained? The Four Checks That Stop Field Leaks

PRODUCT

How Are Protective Cases Tested? Six Stages, Four Owners, and What Each Proves

PROCUREMENT

What should buyers check before purchasing a waterproof case?

TECHNICAL

How should sensitive equipment be secured inside a case?

TECHNICAL

How should equipment cases be selected for outdoor transportation?

TECHNICAL

How Do Seals Help Reduce Dust Entry?

TECHNICAL

How Does Foam Reduce Impact Transmission?

PRODUCT

What affects case seals for a hard-shell equipment case

KNOWLEDGE

What are the common mistakes in case gaskets for equipment transport cases

PRODUCT

What Equipment Benefits From Dustproof Cases? The Five Groups That Pay for the Closure

PRODUCT

What Affects The Impact Protection Of A Case? Six Factors, Ranked

OEM

Can Shockproof Cases Be Customized?

PRODUCT

What Environmental Factors Affect Protective Case Selection? Five Drivers, Ranked

TECHNICAL

How Do Temperature Changes Affect Equipment Cases? Six Mechanisms

TECHNICAL

How Does a Waterproof Case Protect Equipment?

OEM

Can Waterproof Cases Be Customized?

TECHNICAL

How Can Protective Cases Be Used in Harsh Environments?

KNOWLEDGE

IP Rating Selection for Communication Cases

KNOWLEDGE

Kayak/surfboard Sealed Waterproof Dry Case

KNOWLEDGE

Solar Panel Tester Portable Waterproof Case

KNOWLEDGE

Dustproof and Waterproof Instrument Case Design

KNOWLEDGE

Dustproof and Waterproof Medical Case Design

KNOWLEDGE

Dustproof and Waterproof Photography Case Design

Waterproof Cases
PRODUCT FAMILY

Waterproof Cases

Instrument & Equipment Cases
PRODUCT FAMILY

Instrument & Equipment Cases

Electronics Cases
PRODUCT FAMILY

Electronics Cases