Protective Case Basics · Technical

Protective Cases for Medical & Diagnostic Equipment

Quick answer

Specify medical and diagnostic cases by device class, then by the published numbers for one named model - never by a rating word. A rigid thermoplastic shell does the stacking and the knocks; the protection the instrument actually feels comes from the cut interior, and the choice of polypropylene, engineering polypropylene or ABS, of wall thickness between 2.0 and 6.0 mm per model, and of empty mass decide whether a case is carried comfortably or has to be wheeled. KeXin publishes internal and external dimensions, wall thickness, lid and base depth, usable volume, empty mass, gasket construction and the narrow internal width model by model, and leaves an unmeasured field blank. That matters for the words buyers search most: no ingress figure, no shock rating, no disinfectant-compatibility chart, no oxygen-compatibility figure and no temperature range is published for any of the 155 models, so a medical grade waterproof shockproof transport case, an easy-disinfect box or a cold-capable case is a specification you must have tested on the configuration you order, not an attribute you can read off a catalogue page.

Key points

  • Shortlist by device class first: mass, centre of gravity and whether it travels standing decide the shell before colour does.
  • Shell choice is polypropylene, engineering polypropylene or ABS with a wall published per model between 2.0 and 6.0 mm.
  • Shock behaviour comes from the cut foam layout; the shell alone is not a shock rating and we publish none.
  • No ingress, disinfectant-compatibility, oxygen-service or temperature figure is published for any model - specify the test instead.
  • EVA is a carving foam with a closed cell and a firm skin: use it for device nests and restocked pockets, not as a static claim.
  • Wheels and a telescopic handle become the right answer once loaded mass and the carry surface, not empty mass, decide the route.

Device Class First, Case Second

Medical and diagnostic equipment is not one packing problem. An ENT instrument set is small, sharp and expensive per gram. A reagent bottle is glass, liquid and fragile at the shoulder. An infusion pump is a dense block with a screen and a peristaltic door. A mini centrifuge carries a rotating assembly that dislikes permanent set under one corner. An EEG amplifier head is a box of connectors with electrode caps and gel behind it. A portable X-ray unit is a tube head, a detector that must never be loaded on its face, and a battery. An oxygen concentrator is the heaviest thing on the list and the one with a cleanliness requirement attached to its service. What these have in common is only the shell family: a rigid thermoplastic moulding, a compressible gasket on most models, a latch body published as accepting a standard padlock, and an interior cut to the item. Everything else - material, wall, mass, lid depth, whether it rolls - follows from the device. This page works through the twelve device classes buyers actually ask about, against the figures we publish per model, and states plainly which of the searched-for ratings are not published at all.

Medical ENT Examination Tool Latch Box

An ENT kit - otoscope head and handle, a headlight, specula in their rack, a tuning fork, forceps, nasopharyngeal mirrors and a small aspirator - is a low-volume, high-density load of short instruments with finishes that mark easily. The right answer is a small, stiff, latched box with a shallow cut plank rather than a large case with a deep empty cavity, because short instruments move inside deep foam and knock each other. The ABS KX-62810 lists 253 by 182 by 86 millimetres internal on a 4.0 millimetre wall at about 900 grams with 3.2 litres and a published gasket construction, which suits an examination set plus a light source. The polypropylene KX-83612 gives 330 by 260 by 103 millimetres on a 3.3 millimetre wall with 7.6 litres and a 75 millimetre lid over a 28 millimetre base for a speculum rack lying under an instrument row, and the ABS KX-63612 covers 333 by 217 by 114 millimetres at about 1,300 grams with 7.1 litres where a set travels with a battery handle. Latch count is specified per configuration so closure pressure is even across the rim.

Medical Formulation Bottle Foam Lined Plastic Box

Compounding and formulation bottles travel standing, in a carrier, with a cap that must not be torqued by a lid descending on it. Two decisions do the work: a base deep enough that the bottles stand in the base and not across the lid line, and a lining whose pockets locate each body with relief under the shoulder. A foam-lined box that lets bottles touch each other transfers impact from one glass wall to the next, so the pocket wall between bottles is where the protection is. The engineering-PP KX-93221 lists 300 by 200 by 200 millimetres internal on a 5.0 millimetre wall at about 1,230 grams with a 165 millimetre lid over a 35 millimetre base and 9.6 litres, a common size for a dozen 100 to 250 millilitre bottles standing in plank. The KX-83015 gives 245 by 190 by 140 millimetres on a 3.7 millimetre wall with 5.6 litres for a small batch, and the gasketed KX-84825 covers 410 by 360 by 240 millimetres on a 4.2 millimetre wall with a 200 millimetre lid and 28.3 litres for a full formulation run. Closed-cell lining is the practical choice here: a spill sits on top of it and wipes off rather than soaking in.

Laboratory Reagent Bottle Anti-Breakage Box

Glass reagent bottles break at the shoulder and the neck, and they break because of point contact, not because of a general bump. The layout that works is a firm carrier plank with a through-pocket per bottle so the body is supported and nothing presses on the neck, a softer face layer where the glass meets the cut, an individual pocket rather than a shared cavity so a broken bottle does not take its neighbours, and a base that keeps the bottles below the lid line. Sealing is a separate question from breakage: a gasketed rim resists dust and splash, and containment of a spilled liquid is a property of the tray and the absorbent, not of the moulding - state it as a project requirement and we will confirm what is used on the exact SKU. The KX-83615 lists 290 by 220 by 135 millimetres on a 3.3 millimetre wall with an 85 millimetre lid over a 50 millimetre base and 7.4 litres; the thick-wall KX-84215 gives 384 by 285 by 135 millimetres on a 5.0 millimetre wall with 11.8 litres for a shelf of smaller vials; and where larger solvent bottles stand, the KX-93221 with its 165 millimetre lid is the deep-base option.

Medical Portable Infusion Pump Safety Case

An infusion pump is a dense block with a display, a door that must not be pressed, a pole clamp and a battery that adds mass low down, and it usually travels with a set of administration tubing, a charger and the handout. The case is chosen so the pump lies in a cavity that carries it on its chassis, the clamp sits in its own routed pocket, and the tubing and charger ride in a second layer rather than on top of the screen. The ABS KX-63917 lists 360 by 240 by 150 millimetres internal on a 3.8 millimetre wall at about 1,810 grams with 11.2 litres - a single-pump size with room for accessories. Two or three pumps in a ward issue fit the KX-64117 at 393 by 280 by 156 millimetres and about 14.8 litres, or the gasketed polypropylene KX-84416 at 395 by 295 by 135 millimetres on a 4.2 millimetre wall with a 90 millimetre lid over a 45 millimetre base. Where a fleet mixes pumps with consumables, the engineering-PP KX-85215 gives 483 by 363 by 140 millimetres and 19.6 litres.

Medical Mini Centrifuge Shockproof Box

A benchtop or mini centrifuge is the one item on this page whose damage mechanism is compression rather than impact. Rotating assemblies, rotor spindles and lid interlocks dislike sitting on a soft spot for weeks, and a case whose foam is too thin or too soft under the feet lets the unit rest on a housing edge. The answer is a firm carrier layer with a machined or moulded seat under the base, relief cut for the rotor and lid latch, and a layer that carries the tubes, adapter and balance in a separate tray above - which is why a shock-absorbing claim belongs to a specified layout, not to the shell. The gasketed KX-84419 lists 395 by 295 by 165 millimetres internal on a 4.2 millimetre wall with a 120 millimetre lid over a 45 millimetre base and 15.4 litres, a common home for a small clinical spinner with its rotor and tubes. The engineering-PP KX-84820 gives 437 by 308 by 180 millimetres on a 4.5 millimetre wall with 19.4 litres, and where the unit is heavy and the shell must resist a stack, the ABS KX-5021 covers 465 by 315 by 196 millimetres with a 134 millimetre lid over a 62 millimetre base at about 3,430 grams and 24.7 litres.

Medical EEG Machine Protective Trolley Box

An EEG system travels as a head box, an electrode cap or harness, conductive gel, a reference set, a bundle of leads that kinks if it is coiled hard, and often a stand. The connector panel is the fragile surface, so the case must locate the amplifier body and leave the panel unloaded, and the lead bundle needs its own routed channel. Because the whole system crosses a corridor and a car boot, the practical decision is carry rather than volume, and a wheeled shell with a telescopic handle is what lets one person move a full set without a second trip for the cap bag. The gasketed KX-85726 lists 520 by 296 by 210 millimetres internal on a 4.2 millimetre wall with a 155 millimetre lid over a 55 millimetre base, wheels, a published 385 millimetre telescopic-handle travel and 25.8 litres at about 5,600 grams empty. The engineering-PP KX-96027 gives 502 by 337 by 214 millimetres on a 5.0 millimetre wall with wheels and a telescopic handle at about 6,110 grams and 29.0 litres, and the KX-85424 covers 483 by 363 by 190 millimetres on a 4.5 millimetre wall with 26.6 litres for a lighter head box and its accessories.

Medical Portable X-Ray Machine Hard Case

A portable radiography unit is a tube head, a flat-panel detector, a battery and a collimator or stand, and the detector governs the design: it must not carry weight on its face, it dislikes a point load, and a hard case that lets anything rest on the panel has failed before the first exposure. The layout pattern is a deep base that carries the tube head and battery low, a detector laid in its own relieved cavity in the top layer, and separate pockets for the cable and the spare battery, with the whole system closed so nothing bridges the lid line. Volume and stack stiffness are the deciding figures, and a wall published at 5.0 millimetres earns its mass when a case is stacked in a vehicle. The gasketed KX-86127 lists 530 by 360 by 248 millimetres internal on a 5.0 millimetre wall with a 200 millimetre lid over a 48 millimetre base and 37.8 litres; the long KX-87319 gives 650 by 430 by 170 millimetres and 38.0 litres; and where the outfit must roll, the KX-86830 covers 595 by 460 by 255 millimetres on a 4.8 millimetre wall with wheels, a 310 millimetre telescopic handle and 55.8 litres at about 10,160 grams.

Medical Oxygen Concentrator Shockproof Trolley Box

An oxygen concentrator is the heaviest small device on this list, and it comes with a requirement that has nothing to do with the moulding: oxygen-enriching service demands clean, oil-free handling, and material compatibility in that environment is a question for the device manufacturer and your own risk assessment. We publish no oxygen-compatibility figure for any shell or foam in this catalogue, so if your procedure requires one, raise it as a project specification and it is answered by testing on the nominated configuration rather than by a sentence here. What the case does decide is whether the machine arrives without a cracked manifold or a dented sieve-bed housing: a low centre of gravity, a firm carrier layer under the feet, retainers so the unit cannot travel, and wheels with a handle because the loaded mass is well past what one person should carry over a distance. The gasketed KX-85827 lists 500 by 400 by 220 millimetres internal on a 5.0 millimetre wall, wheels, a 295 millimetre telescopic handle and 35.2 litres at about 7,800 grams empty. The KX-87323 gives 650 by 430 by 210 millimetres with a 160 millimetre lid over a 50 millimetre base and 47.0 litres, and the square KX-96127 covers 545 by 545 by 210 millimetres on a 4.8 millimetre wall with wheels and 49.9 litres at about 8,540 grams.

Lightweight Materials For Medical Cases

When a buyer asks for lightweight materials for medical cases, the useful answer is a comparison of three published shell choices plus the arithmetic of the wall. Polypropylene shells are the lightest per litre in ordinary use and tolerate oil, solvent and grit; engineering polypropylene is the same family with a tougher formulation where a case is stacked or knocked repeatedly; ABS is denser and stiffer, so it protects a screen or a connector panel better per millimetre of wall but costs grams. The KX-705 shows the light-carry extreme: a 420 by 270 by 112 millimetre cavity on a 2.1 millimetre wall at about 830 grams for 10.9 litres, published without a gasket. The KX-4616 adds a 3.0 millimetre wall, a gasket construction and a stiffer rim for about 1,395 grams across 19.6 litres. The ABS KX-63413 buys rigidity for a screen at 4.8 millimetres and about 1,680 grams over 6.7 litres. At the small end the KX-1204 is a 2.6 millimetre wall and about 100 grams. Lightness is not free: a thinner wall stacks worse and transmits more point load, so decide which gram matters - the one on the carrier's shoulder or the one on the instrument.

EVA Lining Design For Medical Devices

EVA is one of the lining materials we publish as a standard foam type alongside cross-linked PE, EPE, die-cut and CNC-cut work, and it behaves in a specific way that suits medical kits. It has a closed cell, so a spill sits on the surface and wipes off instead of soaking in; it has a firm skin when carved, so a pocket keeps its shape through repeated issue and return; and it can be laminated in layers so a soft face meets a finished instrument while a firmer carrier takes the mass. Where a device programme needs an exact cavity with a relieved window under a probe, CNC-cut plank is the tighter option and EVA is used as the face layer or for a restocked accessory pocket; where the kit changes between deployments, a pick-and-pluck EVA or PE top over a fixed base is the cheap way to keep the layout current. Two honest limits: we quote foam by zone and contact pressure rather than a blanket density, and an EVA liner is not a static-control or dissipative feature - if the device requires that, it is a separate material specification evidenced by a report on that batch.

Medical Grade Waterproof Shockproof Transport Case

This phrase bundles three claims, and only one of them is a construction detail we can show you. Waterproof: no ingress figure is published for any model in this catalogue, so we do not offer a case as waterproof or dustproof in the sense a specification means it. What is published is a compressible gasket set in a continuous moulded channel on 124 of the 155 models, plus latch count per configuration, because even compression is what makes a rim behave; if your programme needs an ingress figure, it is commissioned as accredited testing on the ordered configuration and quoted as a separate work package. Shockproof: a shock claim belongs to a specified foam layout - a device immobilised in a cut cavity is protected, a loose one inside soft foam is not, because it simply accelerates and strikes the far wall with more energy. Medical grade: there is no medical-grade classification we can attach to a transport shell. Realistic options for this class include the gasketed ABS KX-63912 at 360 by 240 by 104 millimetres and about 1,600 grams for a screen-borne instrument, and the engineering-PP KX-85023 at 463 by 338 by 211 millimetres with 26.4 litres for a kit that travels wet on a trolley.

Medical High Density Easy-Disinfect Plastic Box

Two separate ideas hide in this phrase. Density is a materials data-sheet question, and the shells we publish are polypropylene, engineering polypropylene and ABS with wall thickness recorded per model between 2.0 and 6.0 millimetres; we do not publish a resin density figure or a high-density polyethylene moulding in this range, so a purchasing specification that demands one is answered by naming the requirement, not by assuming it. Disinfectability is a surface and a chemical question: a smooth moulded interior with no fabric liner wipes far more readily than a lined one, closed-cell foam takes a wipe without absorbing it where open-cell material does not, and the practical risk is not the disinfectant but a formulation that attacks a printed outline, an adhesive line or a coloured plank. We make no biocompatibility, cleanroom or sterilisation claim for any model and publish no disinfectant-compatibility chart; if a facility protocol names an agent, quote it to us and the nominated material is confirmed for that SKU. For small wipe-down boxes the gasketed KX-1905 lists 180 by 160 by 40 millimetres at about 250 grams, the KX-3607 covers 355 by 280 by 60 millimetres at about 800 grams, and the engineering-PP KX-3508 gives 344 by 268 by 72 millimetres at about 995 grams.

Device Class To The Figure You Should Check

Device ClassFigure To CheckPublished Example
medical ent examination tool latch boxSmall stiff cavity plus shallow cut plank so short instruments cannot knockKX-62810: 253 x 182 x 86 mm internal, ABS, 4.0 mm wall, about 900 g, 3.2 L, gasket construction published
medical formulation bottle foam lined plastic boxBase depth so bottles stand below the lid line, with relief under the shoulderKX-93221: 300 x 200 x 200 mm internal, 5.0 mm wall, 165/35 mm lid/base, about 1,230 g, 9.6 L
laboratory reagent bottle anti-breakage boxOne through-pocket per bottle; containment is a tray question, not a moulding claimKX-83615: 290 x 220 x 135 mm internal, 3.3 mm wall, 85/50 mm lid/base, 7.4 L
medical portable infusion pump safety caseChassis seat for the pump, screen unloaded, accessories in a second layerKX-63917: 360 x 240 x 150 mm internal, ABS, 3.8 mm wall, about 1,810 g, 11.2 L
medical mini centrifuge shockproof boxFirm machined seat under the feet; the shell alone is not a shock ratingKX-84419: 395 x 295 x 165 mm internal, 4.2 mm wall, 120/45 mm lid/base, 15.4 L
medical eeg machine protective trolley boxConnector panel unloaded plus wheels and published handle travelKX-85726: 520 x 296 x 210 mm internal, 4.2 mm wall, wheels, 385 mm telescopic handle, 25.8 L
medical portable x-ray machine hard caseDetector in a relieved cavity with mass carried low in the baseKX-86830: 595 x 460 x 255 mm internal, 4.8 mm wall, wheels, 310 mm handle, about 10,160 g, 55.8 L
medical oxygen concentrator shockproof trolley boxLoaded carry and retainers; oxygen-service compatibility is a project specificationKX-85827: 500 x 400 x 220 mm internal, 5.0 mm wall, wheels, 295 mm handle, about 7,800 g, 35.2 L
lightweight materials for medical casesGrams per litre at a published wall thickness, and what the thinner wall losesKX-705: 420 x 270 x 112 mm, 2.1 mm wall, about 830 g, 10.9 L, published without a gasket
eva lining design for medical devicesClosed-cell face layer plus firm carrier, quoted by zone not blanket densityKX-92817: 253 x 180 x 152 mm internal, 5.0 mm wall, 125/27 mm lid/base, about 940 g, 5.5 L
medical grade waterproof shockproof transport caseNo ingress figure published; gasket construction and latch count areKX-63912: 360 x 240 x 104 mm internal, ABS, 3.8 mm wall, about 1,600 g, 7.7 L, gasket offered
medical high density easy-disinfect plastic boxPublished shell material and wall, not a density figure or a cleanability ratingKX-3508: 344 x 268 x 72 mm internal, engineering PP, 3.0 mm wall, about 995 g, 5.7 L

Sizing And Interior Rules That Apply Across All Twelve

Six rules repeat across every device class above. Measure the device as it is actually carried - probe connected, cable coiled, battery fitted, clamp attached - and record the extremes rather than the body size. Add working clearance for the cut on every axis, about twenty millimetres, and read the result against published internal length, width and height, not the external figure in a product name. Check the narrow internal width where a model tapers: the KX-4616 lists 302 millimetres at its narrow point against a nominal 338, and a rigid tray that clears the wide section can bind there. Read lid depth separately whenever an item has a screen, a connector panel, a rotor or a standing bottle. Decide the carry format from loaded mass and the surface crossed, not from empty mass alone - a case at 830 grams empty is a hand-carry item and one at 8,540 grams empty is a trolley. Then fix the interior: device on its strongest points, nothing resting on a display, a pocket per accessory, and a layout whose empty shape shows a missing item. Accredited testing of any rating your purchaser demands is quoted against that named configuration, never assumed from the moulding.

Where These Cases Are Used

The buyers of this class of case are rarely hospitals themselves. Device manufacturers ship a unit and its accessories as one issue-able package and need the interior drawing to be the reorder standard. Distributors and integrators build a demonstration or after-sales kit that has to survive a car boot and a waiting room floor. Screening, occupational-health and community inspection programmes build a per-team kit that is issued, returned and restocked weekly. Veterinary practices, ambulance and rescue services, industrial first-aid provision and clinic-to-clinic equipment transfer all draw from the same shells. What they share is the specification method rather than the clinical setting: a named device, a measured packed envelope, a chosen published model, a cut interior, and a stated list of documentation the purchaser has to see. KeXin quotes to that method, publishes measured physical figures per model, and does not attach a clinical, sterilisation, ingress or device-performance meaning to a transport shell.

Customising For A Device Programme

Interior work is the fast path and the one that differs most between programmes. We cut layered plank with a firmer carrier under mass and a softer face against instruments, through-pockets for bottles, relieved windows under a transducer or a detector, routed channels so a lead cannot push its plug into a socket, retainers for anything with a clamp, printed or routed outlines so a missing item is visible at a glance, and colour-coded zones where several people share one kit. A fixed cut base with a pick-and-pluck top is the standard answer for a kit whose consumables change between issues. Shell-side configuration - colour, printed or in-mould logo, extra latches, a document holder, a shoulder strap, a breather option, buyer-branded packaging - is quoted per build, and the tooling path differs by item. Send the packed-state dimensions, a photograph of the kit with a scale reference or a physical sample, the hardware you want, and the annual quantity; we confirm the nominated model's material datasheet rather than assuming one grade across the catalogue, and we will say plainly when a stock envelope is closer and cheaper than a new mould.

Procurement Notes: Wholesale Terms, MOQ And Lead Time

KeXin New Materials (Guangdong) Co., Ltd. supplies on wholesale and OEM or ODM terms only, on EXW or FOB. There is no retail channel, no delivered-duty-paid quotation and no overseas warehouse, so freight and clearance sit with the buyer. Minimums are layered: one piece on a standard model, one piece for a custom foam layout so a single unit can be proven before a fleet is fitted out, near 300 pieces for colour, logo or OEM production, and near 3,000 pieces per component for a dedicated new mould. A first OEM article on existing tooling runs about 45 days and a new mould about 125 days from approved drawings, with a 30 per cent deposit and the balance before shipment after inspection. Third-party inspection at our facility is welcome. Internal and external dimensions, wall thickness, lid and base depth, usable volume, empty mass, narrow internal width, gasket construction and padlockable latch bodies are published per model; pallet figures are calculated from the carton footprint against your pallet size, and container loading is supplied with the quotation. Where a figure has not been measured on the model you order, we say so and quote the test rather than estimating. Enquiries go to Fred Zhao or the KeXin Sales Team, WhatsApp +86 135 3588 0002.

Two buyer searches, answered row by row from the published data

Both phrases ask the same page a different question, so each is answered on its own row. Every number below comes from the published specification table - a figure for a named model, a count across a named group, or a stated percentage gap between two published columns - and where the table holds no value we say that instead of filling it in.

SearchWhat We Publish
medical equipment case size selectionMedical equipment case size selection is arithmetic on published columns, not a choice of letter sizes. Across the 155 models the internal volume ladder runs from 0.3 to 139.5 litres: 42 models publish under 10 litres, 42 between 10 and 20 litres, 47 between 20 and 40 litres, 18 between 40 and 70 litres and 6 above 70 litres. The 71 shells listed in the medical-equipment-cases category start at 20.2 litres, so a compact diagnostic set is picked from the wider catalogue - KX-62810 publishes 253 x 182 x 86 mm internal with 4.0 litres internal and 3.2 litres usable on a 4.0 mm ABS wall, and KX-3508 publishes 344 x 268 x 72 mm internal, a 3.0 mm wall, about 995 g empty and 6.6 litres internal against 5.7 litres usable. Measure the device as it is actually carried - probe connected, cable coiled, battery fitted, clamp attached - add about 20 mm of working clearance on each axis for the cut, then read that against internal length, width and height rather than the external figure. Three columns get skipped and should not be: the narrow internal width, published for 36 models from 70 mm to 308 mm (240 mm on KX-3508, 243 mm on KX-705); the lid-to-base split, published for 100 models (125 mm over 27 mm on KX-92817, 120 mm over 45 mm on KX-84419); and usable volume, which sits a median 15 per cent below the internal figure across the 155 models and 20.3 per cent below on KX-92817. The internal-to-external difference is not a rounding error either - median 26 mm on length, 57 mm on width and 15 mm on height - so a rack sized from a catalogue name loses the wall, the latch and the hinge. Empty mass is published for 93 models from 100 g to 15,320 g, wall thickness for 148 from 2.0 mm to 6.0 mm with a median of 3.9 mm, carton data for 64 models, and pallet figures are calculated from the carton footprint against your pallet size rather than published as a tested value.
medical diagnostic device case with custom foamA medical diagnostic device case with custom foam is the standard route rather than an exception: all 155 published models record custom foam, custom foam thickness, die-cut work and CNC-cut work as available, with the foam vocabulary published as Pick and Pluck, die-cut and CNC-cut in EVA, PE or EPE, laid out as top foam, base foam, egg-crate or convoluted, layered and custom cut. What we need to start is recorded per model as a drawing, a photograph of the packed kit or the unit itself. The floors are published too: 1 piece for a standard shell or a custom foam layout, 300 units for a colour or a printed logo, and a genuinely new shell size from 3,000 pieces per component at about 125 days, against about 45 days for a first OEM sample on a mould already in service. Three published shells show what the cut does to the envelope. KX-63917 lists 360 x 240 x 150 mm internal, ABS with a 3.8 mm wall, about 1,810 g empty, 13.0 litres internal and 11.2 litres usable - the 1.8 litres between those two columns is what the carrier plank and face layer consume, and it is the number to design an infusion-pump kit against. KX-84419 lists 395 x 295 x 165 mm internal, a 4.2 mm wall, 19.2 litres internal and 15.4 litres usable with the depth split published as a 120 mm lid over a 45 mm base. KX-85726 lists 520 x 296 x 210 mm internal, a 4.2 mm wall, about 5,600 g empty, 32.3 litres internal and 25.8 litres usable, published on two wheels with a 385 mm telescopic pull. Shock behaviour is recorded for every model as a property of the specified foam layout, not of the moulding - the note published against impact resistance is the wall thickness plus no claimed drop height - and a compressible gasket in a continuous moulded channel is recorded on 124 of the 155 models and as none offered on 31. The latch body accepting a standard padlock is recorded on all 155; latch count is specified per configuration.

How the size ladder is read before the interior is drawn

The bands are only a shortlisting device; the decision is made on one named model's columns. Where a kit is long rather than deep, 35 models publish at least 500 mm of internal length, which covers stands, poles, lead bundles and instrument bars in one plane instead of folded. Where a fleet is stacked in a store, 136 of the 155 bodies are marked stackable and the 19 published on wheels are the ones marked non-stackable, so a mixed fleet is planned on floor area, not on a shelf grid. Where the same shell has to serve several devices, the pluck layer is the cheap answer and the die-cut nest is the one that shows a missing item at a glance.

The second reading is mass against role. Below about 2 kg empty a shell is a carried item - KX-62810 at about 900 g, KX-3508 at about 995 g, KX-92817 at about 940 g and KX-4616 at 1,395 g all sit there. Between 5 kg and 11 kg the published answer is usually wheels and a pull height, which is why KX-85726 (5,600 g, 385 mm), KX-85827 (about 7,800 g, 295 mm), KX-86830 (10,160 g, 310 mm) and KX-88442 (15,320 g, 295 mm) are the four models on this page whose figures include both a wheeled base and a published telescopic pull. Empty mass is not published for every model - 93 of 155 carry a figure - so where a quotation depends on carry weight we confirm it on the named article rather than assuming it from the size band.

Size band, published example, and the figure that decides it

Size BandPublished ExamplePublished FiguresWhat It Decides
Under 10 litresKX-62810253 x 182 x 86 mm internal, 275 x 226 x 100 mm external, ABS, 4.0 mm wall, about 900 g empty, 4.0 L internal and 3.2 L usable, gasket recorded, 480 x 293 x 550 mm cartonShort instruments in a shallow plank: a deep cavity lets small steel knock, so the cut matters more than the shell here
10 to 20 litresKX-63917360 x 240 x 150 mm internal, 389 x 295 x 165 mm external, ABS, 3.8 mm wall, about 1,810 g empty, 13.0 L internal and 11.2 L usable, gasket recorded, 625 x 405 x 717 mm cartonOne dense device plus its tubing and charger: the 1.8 L difference is the interior allowance already built into the published usable figure
20 to 40 litresKX-85726520 x 296 x 210 mm internal, 576 x 363 x 257 mm external, PP, 4.2 mm wall, 5,600 g empty, 32.3 L internal and 25.8 L usable, lid 155 mm over base 55 mm, two wheels, 385 mm pull, marked non-stackableA multi-part system that crosses a corridor: the amplifier body is located, the connector panel is left unloaded, and the leads get their own channel
40 to 70 litresKX-85827500 x 400 x 220 mm internal, 588 x 475 x 267 mm external, PP, 5.0 mm wall, about 7,800 g empty, 44.0 L internal and 35.2 L usable, lid 175 mm over base 45 mm, two wheels, 295 mm pullHeaviest small devices in one issue: loaded mass and the carry surface decide the route, and no oxygen-service compatibility figure is published for any shell or foam
70 litres and aboveKX-88442740 x 518 x 364 mm internal, 843 x 592 x 415 mm external, PP, 5.0 mm wall, 15,320 g empty, 139.5 L internal and 111.6 L usable, lid 320 mm over base 44 mm, two wheels, 295 mm pull, marked non-stackableThe largest published envelope in the catalogue; the 27.9 L gap to usable volume is the interior, so a fleet of these is a trolley plan rather than a shelf plan

What neither row states, and the terms both rows are quoted on

The specification table records waterproof, dust resistance, UV resistance, temperature range, stack load, load capacity and protection rating as not measured for all 155 models, so neither row above carries an ingress figure, a temperature limit, a stacking load or a drop height. No resin density figure, no disinfectant-compatibility chart, no oxygen-compatibility figure and no cleanability rating is published for any shell or foam in this catalogue; where a programme needs one, accredited third-party testing against the exact model and configuration can be commissioned as a separate work package and we do not claim a result we have not measured. Impact is stated only as the wall thickness published for the named model - 4.0 mm on KX-62810, 3.8 mm on KX-63917, 4.2 mm on KX-85726, 5.0 mm on KX-85827 - and shock performance is a property of the specified foam layout. The case is transport packaging: no clinical, sterilisation or device-registration statement is made, and the device inside remains its registrant's responsibility.

Terms are the same whichever row applies: wholesale and OEM or ODM only, EXW or FOB from Guangdong, China, with a 30 per cent deposit and the balance after inspection. There is no retail channel, no delivered-duty-paid quotation and no overseas warehouse, so freight and clearance sit with the buyer. The published floors are 1 piece for a standard shell or a custom foam layout, 300 units for colour or logo, and 3,000 pieces per component with about 125 days for a new mould, against about 45 days for a first OEM sample on a mould already in service. KeXin New Materials (Guangdong) Co., Ltd. quotes size selection and foam layout against your packed-state dimensions, and third-party inspection of finished goods or an audit of the factory is welcome.

Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case
Custom foam liner being prepared for a protective case

Customisation

Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.

Procurement considerations

QuestionWhat to send us
Which shell fits?Equipment L × W × H as packed, plus required clearance per axis
What does it cost?Order quantity and estimated annual quantity — the two drive different answers
Is tooling needed?Whether an existing shell clears the envelope with usable foam depth
Lead time?Your required delivery date, not just the order date
Certification?The exact standard your tender names — we will say whether we can test to it
Freight?Destination and preferred terms; carton and pallet data supplied with the quotation

Comparison and selection guide

The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.

SituationWhat To Do
Clinical environmentClosed-cell foam or a wipeable tray; no open-cell pluck foam.
Emergency useLatches that open with one hand and a lid that stays up unaided.
High-value deviceDeeper base foam, a separate transducer zone, and a documented drop test if required.
  • Size on internal dimensions plus clearance, never on a product name.
  • Choose the carrying method before the shell: it changes the series, not just the price.
  • Specify the interior last, and decide up front whether the end user will reconfigure it.
Entity relationships

Protective Cases for Medical & Diagnostic Equipment relates to Protective Case Basics. Related families: Medical Equipment Cases / Instrument & Equipment Cases / Electronics Cases / Rolling Cases / Custom Protective Cases / Equipment Transport Cases / Waterproof Cases. Related sectors: field and industrial equipment. Continue in the Protective Case Basics cluster.

Next step

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.

Talk To The Manufacturer→Find the Right Case

FAQ

Frequently asked on this topic

Which case fits medical & diagnostic equipment?

By device class, against a published figure rather than a category name. A short instrument set suits the ABS KX-62810 at 253 x 182 x 86 mm; an infusion pump suits the KX-63917 at 360 x 240 x 150 mm; bottles standing suit the deep-lid KX-93221 at 300 x 200 x 200 mm; a mini centrifuge suits the KX-84419 with a 120 mm lid; an EEG head box that has to roll suits the KX-85726 with wheels and a 385 mm telescopic handle; a portable X-ray outfit suits the KX-86127 or the rolling KX-86830; and an oxygen concentrator suits the KX-85827 or KX-96127. In every case the interior is then cut to the customer's actual kit.

What internal dimensions do buyers of medical & diagnostic equipment need?

Internal length, width and height that clear the device as packed - probe connected, cable coiled, battery and clamp fitted - with about twenty millimetres of working clearance per axis for the cut, plus a lid depth that no screen, connector panel, rotor shoulder or standing bottle lifts, plus an external size that still fits the trolley shelf, vehicle bay or store rack it lives on. KeXin publishes internal and external dimensions, wall thickness, lid and base depth, usable volume, empty mass and the narrow internal width per model, and leaves unmeasured fields blank instead of filling them with a series average.

Can the foam insert be custom cut for these items?

Yes, and for medical payloads it usually should be, because the insert rather than the shell carries most of the protective behaviour. We cut cross-linked PE, EVA or EPE plank in layers: a firm carrier under mass, a softer face against instruments, through-pockets for bottles, relieved windows under a detector or a transducer, routed channels for lead sets, retainers for clamps, and printed outlines so a missing item shows as an empty pocket. A fixed base with a pick-and-pluck top suits kits that change between issues. Send a drawing, a scale photograph of the packed kit or a physical sample; custom foam is quoted from one piece on existing moulds.

What MOQ and lead time apply to this category?

One piece on a standard model and one piece for a custom foam layout, so a programme can prove an interior before committing a fleet. Colour, logo and OEM production begin near 300 pieces, and a dedicated new mould near 3,000 pieces per component. A first OEM article on existing tooling takes about 45 days and a new mould about 125 days from approved drawings, on EXW or FOB terms with a 30 per cent deposit and the balance before shipment after inspection. Wholesale and OEM only: no retail, no delivered-duty-paid terms, no overseas warehouse.

Which shell material and sealing suit this use in the field?

Polypropylene is the light per litre and tolerates oil, solvent and grit; engineering polypropylene is the tougher formulation for stacked or hard-handled kits, as in the KX-84820, KX-85023 and KX-96027; ABS buys stiffness per millimetre for screens and connector panels, as in the KX-62810, KX-63912 and KX-5021. Wall thickness is published per model between 2.0 and 6.0 mm. A compressible gasket in a continuous moulded channel is offered on 124 of the 155 models and the latch body is published as accepting a standard padlock; both are stated per model rather than assumed, and neither is presented as an ingress figure, because none is published.

Is any KeXin medical case waterproof, shockproof or medical grade?

None of those three is a claim we can make for a transport shell, and pretending otherwise would waste your tender response. No ingress figure is published for any model, so we describe construction instead: a gasketed rim with even latch compression that resists dust and splash. No shock rating is published either, because shock behaviour is a property of a specified foam layout with the device immobilised, not of the moulding - a loose item inside soft foam still strikes the far wall. There is no medical-grade classification attached to a case. If your specification names an ingress code, a drop height or a cleanability standard, we quote accredited testing of that named configuration as a separate work package.

Can a case be used as an oxygen concentrator or disinfectant-contact container?

Mechanically yes, with two honest limits. A concentrator is heavy and its manifold and sieve-bed housing dislike a point load, so choose a thick-wall model with a firm carrier seat, retainers and wheels - the KX-85827, KX-87323 or KX-96127 - but oxygen-enriching service requires oil-free handling and material compatibility that we do not publish and cannot certify for any shell or foam; that is a question for the device manufacturer and your own assessment. The same applies to a named disinfectant: a smooth moulded interior and a closed-cell lining wipe readily, but no disinfectant-compatibility chart is published, so give us the agent and we confirm the nominated material for that exact SKU.

Related

Continue in Protective Case Basics

TECHNICAL

How To Choose A Protective Case: The Seven Numbers That Decide It

TECHNICAL

What A Protective Case Is Made Of: Shell, Seal, Hardware And Foam

TECHNICAL

How a Protective Case Matching Engine Works

KNOWLEDGE

Case Hardware: Latches, Hinges, Handles and Wheels

KNOWLEDGE

What Is a Military Equipment Case? The Five Subsystems That Do the Work

FACTORY

Can Electronics Cases Be Manufactured According to Equipment Dimensions?

PRODUCT

What type of case is suitable for sensitive electronics?

KNOWLEDGE

What factors affect protective case selection?

KNOWLEDGE

What Is a Photography Equipment Protective Case?

PRODUCT

What Case Size Is Suitable for Camping Equipment? Sizing by Packed Envelope, Not by Litres

PRODUCT

What Factors Affect Hunting Equipment Case Selection? Seven Inputs And The Models That Answer Them

TECHNICAL

How Should Camping Equipment Be Stored In Protective Cases?

PRODUCT

What Equipment Benefits from Outdoor Protective Cases?

KNOWLEDGE

What Is an Outdoor Protective Case? The Shell That Works Outside

TECHNICAL

How Can Foam Inserts Improve Equipment Organization? A Geometry Answer

COMMERCIAL

Protective Cases for General Protective Case Solutions Equipment

TECHNICAL

Cases for Hand Tools, Power Tools & Hardware in Automotive Service Bays

APPLICATION

Protective Cases for Outdoor & Field Operations Equipment for High-Precision Work

COMMERCIAL

Protective Cases for Outdoor & Field Operations Equipment for Harsh Climates

COMMERCIAL

Protective Cases for Industrial Equipment

COMMERCIAL

Cases for Medical & Diagnostic Equipment in Automotive Service Bays

COMMERCIAL

Cases for Audio, Camera & Stage Gear on Film Productions

APPLICATION

Cases for Audio, Camera & Stage Gear in Live Streaming Kits

COMMERCIAL

Cases for Drones & UAV Equipment

COMMERCIAL

Cases for Optics & Precision Instruments

APPLICATION

Cases for Medical & Diagnostic Equipment

COMMERCIAL

Cases for Test Equipment

TECHNICAL

Cases for Hand Tools, Power Tools & Hardware for Hydraulic Work

APPLICATION

Cases for Outdoor & Field Operations Equipment for Camping & Overlanding

APPLICATION

Cases for Optics, Cameras & Precision Instruments

APPLICATION

Cases for Battery Packs, Power Supplies & Energy Equipment

TECHNICAL

Protective Cases for Battery Packs, Power Supplies & Energy Equipment and Outdoor

COMMERCIAL

Protective Cases for Hand Tools, Power Tools & Hardware for Workshop Assemblies

APPLICATION

Protective Cases for Radio, Network & Telecommunications Equipment

APPLICATION

Cases For Optics, Cameras & Precision Instruments Used With Medical Devices: Device-By-Device Selection

COMMERCIAL

Cases For Automotive & Rail Equipment: A Wholesale Buying Guide

TECHNICAL

How Should Outdoor Equipment Be Organized Inside a Case? A Condition-First Layout

PRODUCT

What affects case locks for a hard-shell equipment case

PRODUCT

What protective case is suitable for scientific instruments?

PRODUCT

What Camping Equipment Can Be Organized in a Hard Case? A Zone-by-Zone Sizing Guide

TECHNICAL

How Should Cameras and Lenses Be Protected During Transport? A Measured Layout Guide

TECHNICAL

How Can Sensitive Instruments Be Protected From Impact?

TECHNICAL

How Should Scientific Equipment Dimensions Be Measured?

KNOWLEDGE

Fire and Rescue Equipment Case

KNOWLEDGE

Handheld LED Light Stick Protective Box: Fit Guide

KNOWLEDGE

EDC Outdoor Tool Shockproof Protective Box, Explained

KNOWLEDGE

Film Focus Puller & Accessories Safety Case Guide

KNOWLEDGE

Outdoor Emergency Survival Gear Safety Box

KNOWLEDGE

Drone Arm Protective Case

KNOWLEDGE

Stackable Industrial Case Design: Stack, Seal, Handle

KNOWLEDGE

Professional Drone Combo Multi-Battery Hard Case

KNOWLEDGE

Relay Protection Tester Case: Sizing, Foam And Freight

KNOWLEDGE

Medical Ultrasound Probe Protective Case

KNOWLEDGE

Tire Inspection Tool Case

KNOWLEDGE

Cinema 8K Camera Protective Flight Case Alternative

KNOWLEDGE

Display Accessories Transport Case

KNOWLEDGE

Electronic Device Protective Case With Wheels And Trolley

Medical Equipment Cases
PRODUCT FAMILY

Medical Equipment Cases

Instrument & Equipment Cases
PRODUCT FAMILY

Instrument & Equipment Cases

Electronics Cases
PRODUCT FAMILY

Electronics Cases