How can sensitive instruments be protected from impact?
Protect a sensitive instrument in three separable layers, and do not confuse them. The first layer is stopping distance: the cushion between the item and the shell decides how hard the instrument is decelerated when the case is dropped, so it is a thickness and grade decision before it is a material decision. The second layer is load path: an item that bridges the lid line, or that rests on one rigid foot, is loaded by geometry rather than by padding, and no thickness fixes that. The third layer is the shell itself, which contributes wall geometry and rim stiffness, not a rating - wall thickness is published on 148 of our 155 models between 2.0 and 6.0 millimetres, while no drop height, no cushioning level and no protection code is published for any model, because those are tests and we do not invent test results. So the honest answer to sensitive instruments protected impact is: choose the interior first, check the height against the published base depth, then choose the shell, then write the exposure as a test on the ordered configuration. Outdoor sensitive instruments protected impact adds a sequence the laboratory rarely reproduces - vehicle boot, hand-off, kerb, tripod, and cold that stiffens both polymer and foam - which is exactly why the field sequence should be the test you commission rather than an adjective on a datasheet.
Key points
- Cushion thickness is the first decision: peak deceleration is a stopping-distance problem, and a 50 mm base layer behaves very differently from a 20 mm one under the same packed mass.
- Check item height against the published base depth: lid and base depths appear together on 100 models and sum exactly to the internal height, so an item that bridges the joint line loads the closure.
- Wall thickness is recorded on 148 of 155 models between 2.0 and 6.0 millimetres; it explains rim stiffness and stacking behaviour, not survivability, and no drop height is claimed without a test.
- Shock protection and impact resistance are published as construction options on all 155 models, not as measured ratings: the shell alone is not a shock rating, and the foam layout is what makes the difference.
- Thirty-one models publish no gasket offered at all, so an interior that seals the item in a pocket matters more than a thicker shell when dust is the exposure.
- Specify the exposure as a test on the nominated SKU and interior; we quote accredited third-party testing as a separate work package instead of printing a number we do not have.
What Sensitive Instruments Protected Impact Actually Asks
Read as a search phrase, sensitive instruments protected impact is really three questions that procurement documents usually collapse into one. The first is what happens to the instrument at the moment of contact: how fast it is stopped, and over what distance. The second is where the force goes: whether it is spread across a cushioned face or concentrated on a connector, a knob, a lens barrel or the corner of a chassis. The third is what the case itself survives, because a shell that cracks on the second impact protects nothing on the third. Those three have different answers, different costs and different evidence, and the reason so many field kits fail is that a buyer chooses a shell from a catalogue picture and treats the interior as an afterthought. Our own catalogue is built to make the layers visible: internal and external dimensions, wall thickness, lid and base depth, volumes and net mass are published per model, while every protection field that would require a test - ingress code, drop height, cushioning level, stack load - is published as unmeasured or as a construction option. That is the position we intend to keep stating, because a number we have not measured is worth nothing to the person who has to defend a failure.
Layer One: Stopping Distance Decides What The Instrument Feels
In a simple cushioning model the peak deceleration an item experiences is set by the fall height and the distance over which it is stopped, so doubling the working thickness of the cushion roughly halves what the instrument sees. That is why thickness is decided before material. Our foam page works the same arithmetic with a real example: for a 15 kilogram assembly, a 20 millimetre base layer is close to fully compressed in a modest free drop, which means the equipment is effectively hitting the shell, while a 50 millimetre base layer under the same mass keeps compression in reserve. The published interior options across this catalogue are pick-and-pluck, die-cut, CNC-cut, EVA, PE and EPE, in top foam, base foam, egg-crate or convoluted, custom-cut and layered constructions, and bonded layers of different grades are how you get a soft face against a finished surface with a firmer carrier underneath. Two failure modes come from ignoring this layer. One is under-thickness: plenty of foam, but the item bottoms out on every lorry pothole and the damage accumulates as a cracked mount or a drifting calibration. The other is creep: a soft grade chosen for its initial feel that takes a permanent set under sustained mass over months on a shelf, so the stopping distance that was designed in June is gone by January. Density and grade govern the second; only thickness governs the first.
Layer Two: Load Path Beats Padding Every Time
The most common avoidable damage is not a soft drop onto a thick cushion; it is a geometry problem. If an instrument is taller than the base depth, it bridges the joint line, and a drop into the base transfers load through the item into the lid, the latches and the gasket rather than into the foam. Our data lets you check this before ordering: lid depth and base depth are published together on 100 of the 155 models, and on every one of those 100 the two figures sum exactly to the published internal height. KX-92817 publishes 125 millimetres of lid over 27 millimetres of base on a 152 millimetre interior, so an item 120 millimetres tall is not a base-cushioned item at all - it is a lid-loaded one, and it needs either a deeper shell or a layout that puts the mass in the lid half deliberately. The same arithmetic applies to the interior width: 36 models publish a narrower internal width than the nominal one, between 8 and 37 millimetres narrower, because the moulding tapers toward the rim, and a rigid chassis that fits at the base can bind at the joint. Third point of failure is a point load: a stand, a probe, a carrying handle bolted through the case wall, or an accessory clipped to the inside concentrates force on a small area. Capture the item on a machined face, keep connectors and knobs off the closure line, and pack loose accessories in their own pocket rather than beside the instrument.
Layer Three: What The Shell Contributes, And What It Does Not
A moulded thermoplastic shell contributes three things: it spreads a local load around the rim, it keeps abrasion and grit away from the interior, and it maintains the geometry that the cushion depends on. What it does not contribute is a survivability number. Wall thickness is published on 148 of 155 models between 2.0 and 6.0 millimetres; the remaining seven publish none, and we do not extrapolate. Read alongside the internal figures, the wall tells you what you are trading: the engineering-polypropylene KX-5321 builds a 481 by 373 by 192 millimetre interior on a 5.8 millimetre wall at about 4,810 grams empty, while the polypropylene KX-3207 gives a 308 by 230 by 64 millimetre interior on a 3.0 millimetre wall at about 570 grams, and the KX-2005 at 2.0 millimetres and about 175 grams is the kind of light shell that a person will actually carry on day seven. Material is a real variable here: 94 models are polypropylene, 38 engineering polypropylene, 22 ABS, and one is published as PP / ABS, which is why we treat material and wall as two separate columns rather than one quality signal. Shell mass is published on 93 models, from 100 grams to 15,320 grams, median about 1,480 grams, which is the honest way to show what a thick wall costs a field team that walks everywhere.
Published Construction For The Models Buyers Compare Most
| Model | Internal Mm | Wall Mm | Lid Base Mm | Net Weight G | Gasket | Why It Is Listed |
|---|---|---|---|---|---|---|
| KX-1905 | 180 x 160 x 40 | 3.0 | 25 / 15 | 250 | Published, continuous moulded channel | A flat two-part interior where a hand meter or a set of probes sits below the joint line without any lid cushion. |
| KX-2811 | 253 x 180 x 98 | 5.0 | 71 / 27 | 890 | Published, continuous moulded channel | Thick-wall small shell; note that the base is 27 mm, so a tall item loads the lid, not the foam. |
| KX-92817 | 253 x 180 x 152 | 5.0 | 125 / 27 | 940 | Published, continuous moulded channel | Engineering polypropylene on a 5.0 mm wall with a deep lid - a survey instrument layout, not a flat pack. |
| KX-62810 | 253 x 182 x 86 | 4.0 | Not published for this shell | 900 | Published, continuous moulded channel | ABS shell with a 4.0 mm wall, shipped in cartons of 10 at 480 x 293 x 550 mm. |
| KX-3315 | 303 x 224 x 135 | 4.1 | 100 / 35 | 1670 | Published, continuous moulded channel | Mid-size engineering-polypropylene shell where the base depth leaves real cushion under an instrument body. |
| KX-64618 | 430 x 290 x 165 | 4.7 | 140 / 25 | 2775 | Published, continuous moulded channel | ABS on a 4.7 mm wall with a 140 mm lid: an item under 25 mm tall sits in base foam, anything more is lid-carried. |
| KX-4821 | 447 x 312 x 194 | 4.5 | 144 / 50 | 3670 | Published, continuous moulded channel | A 50 mm base with a thick wall, chosen when the packed kit is mass rather than a hand instrument. |
| KX-5321 | 481 x 373 x 192 | 5.8 | 43 / 149 | 4810 | Published, continuous moulded channel | The deepest published base in this group: 149 mm of base with the lid above the joint line. |
| KX-2614 | 240 x 200 x 120 | 2.2 | 60 / 60 | 460 | None offered on this shell | The carry-economy end of sensitive instruments protected impact: light, even 60/60 split, and no sealing joint to protect. |
| KX-1204 | 115 x 78 x 32 | 2.6 | 16 / 16 | 100 | None offered on this shell | A 0.3 litre accessory shell - the right answer when the item is a spare sensor head, not the instrument. |
Outdoor Sensitive Instruments Protected Impact: The Sequence That Breaks Them
Outdoor sensitive instruments protected impact is a harder problem than the laboratory version, because outdoors the case is subjected to a sequence rather than a single event: lifted out of a boot, handed to a colleague and missed, set down on kerb stone, knocked against a tripod leg, loaded on a rack with three other cases, then driven on an unsealed road. Each of those is a different impulse to a different part of the shell, and the catalogue cannot tell you which one wins, because we publish no drop height and no cushioning level for any model. What the outdoor sequence does tell you is which construction features earn their cost. A gasketed joint keeps grit out of the interface that has to compress; 124 of the 155 models publish a compressible gasket in a continuous moulded channel, and 31 publish none offered on that shell, which is a real choice a buyer makes knowingly. A lid that opens without exposing the instrument to falling debris matters when the site is windy. Feet, published as measured across the range, keep the shell face off wet ground. Cold is the one outdoor variable that changes the cushion arithmetic rather than the contamination arithmetic, and it is where our published data stops: no temperature range is recorded for any model, so a polymer and a foam that behave at room temperature may behave differently at the first frost, and that difference belongs in your test list, not in our brochure.
Selection Guidance: Six Decisions In The Right Order
Decision one: the mass of the packed item and the height of the item, in that order, because mass decides grade and carrier stiffness while height decides whether the base or the lid carries the load. Decision two: the working thickness under the item and around its faces, checked against the published base depth. Decision three: whether the item is captured on a machined face or simply lying in a plucked bed - a captured item cannot travel across the interior and hit a wall that was never meant to take it. Decision four: the shell, read as wall, material and closure layout rather than as a rating, using the published columns above. Decision five: the exposure you cannot see in the data - temperature, dust, wash-down, UV - written as a short list of tests against the nominated SKU and interior. Decision six: logistics, because a case that is too heavy to carry gets left in the vehicle, and a case that is too big for the rack gets stacked on its lid. The internal volume figures published on every model, and the usable interior volume that sits below it on 154 of 155, exist to make that last decision arithmetic instead of opinion.
What We Do Not Claim, And Why That Is Useful
Stated plainly, so nobody discovers it after an incident. For all 155 models: shock protection and impact resistance are published as construction options, with the note that a specified foam layout is required and that the shell alone is not a shock rating; no drop height is claimed without a test. No protection code of any kind is stated on any model, and our own record says accredited testing is quoted per configuration. No stack load in kilograms and no load capacity are published for any model. No ingress, ultraviolet or temperature figure is published for any model. The one protection field recorded as measured on every model is corrosion behaviour, and it is measured because it follows from material rather than from a test: a thermoplastic shell has no ferrous corrosion path, and hardware is metal or polymer by configuration. This is not a hedging exercise. A purchaser who is told everything passes everything has no way to find out which sentence is true, and a purchaser who is shown which fields are measured, which are options and which are empty can write a specification that actually tests the exposure they have. If your procedure requires a documented free-fall height onto a named surface with a named pass criterion, we will quote that work on the exact SKU and the exact cut interior, through an accredited laboratory, as a separate line item.
Custom Interiors, Tooling And Lead Time
The interior is where the protection is designed, and it is the part we change most often. Custom foam, custom thickness, custom shape, CNC cutting and die cutting are published as available on every model, with pick-and-pluck, EVA, PE and EPE offered as the base options and bonded layers used where a soft face and a firm carrier are both needed. To cut an interior we need a drawing, a scale photograph of the packed kit, or a physical sample - that requirement is recorded per model rather than invented for you, and the fastest route is usually the photograph with a ruler in shot. Minimums: one piece on a standard model, one piece for a custom foam layout, about 300 pieces where a logo, a colour or an OEM build is involved, and about 3,000 pieces per component if you want a dedicated new mould. Lead time is about 45 days for a first OEM article on existing tooling and about 125 days from approved drawings for a new mould, with a 30 per cent deposit and the balance after inspection. Changing a mould is what a new geometry costs; changing an interior is what most impact problems actually need, and it is the cheaper decision by two orders of magnitude.
Wholesale Terms, Inspection And Contact
KeXin New Materials (Guangdong) Co., Ltd. supplies on wholesale and OEM or ODM terms only. Quotations are EXW or FOB: there is no retail channel, no delivered-duty-paid price and no overseas warehouse stock, so freight and import handling stay with the buyer or their forwarder. Third-party inspection is welcome and pre-shipment inspection by your own agent is the normal route; a factory audit is not a problem for us. Send the instrument mass, the packed height, the internal envelope you need, the exposure list, the annual quantity per size and any test your purchaser must see evidenced, and we will answer with the published record of the nominated model, an interior proposal, and a separate quotation for any accredited testing rather than a claim we cannot source. Contact Fred Zhao or the KeXin Sales Team, WhatsApp +86 135 3588 0002. Related pages on this site cover how foam reduces impact transmission, how foam thickness is chosen, what impact testing and drop testing are for, and how to read a protective case datasheet, which together answer most of what a specification needs before it reaches us.




Customisation
Everything described above is configurable on a standard shell: interior layout (pick-and-pluck, die-cut or CNC-cut), foam grade and thickness, colour, logo method, latch and lock count, pressure-equalisation valve, cable ports, document holder and identification plate. A bespoke exterior geometry requires a new mould — 125 days, from 3,000 units per moulded component.
Procurement considerations
| Question | What to send us |
|---|---|
| Which shell fits? | Equipment L × W × H as packed, plus required clearance per axis |
| What does it cost? | Order quantity and estimated annual quantity — the two drive different answers |
| Is tooling needed? | Whether an existing shell clears the envelope with usable foam depth |
| Lead time? | Your required delivery date, not just the order date |
| Certification? | The exact standard your tender names — we will say whether we can test to it |
| Freight? | Destination and preferred terms; carton and pallet data supplied with the quotation |
Comparison and selection guide
The tables on this page exist because a protective case is chosen by comparing three things: the envelope, the environment and the handling chain. Where no table applies, the rule below is.
| Situation | What To Do |
|---|---|
| Marine or wet | Sealed configuration with a drain-friendly interior and stainless hardware. |
| Dry and dusty | A close-fitting rim and a lid that can be opened one-handed without spilling contents. |
| Carried far | Under 10 kg packed, with a padded handle or shoulder webbing. |
- Size on internal dimensions plus clearance, never on a product name.
- Choose the carrying method before the shell: it changes the series, not just the price.
- Specify the interior last, and decide up front whether the end user will reconfigure it.
How can sensitive instruments be protected from impact? relates to Protective Case Basics. Related families: Outdoor Protective Cases / Instrument & Equipment Cases / Field Equipment Cases / Electronics Cases / Equipment Transport Cases / Custom Protective Cases / Military Protective Cases / Tactical Equipment Cases / Optical Equipment Cases / Medical Equipment Cases. Related sectors: field and industrial equipment. Continue in the Protective Case Basics cluster.

This page is written from our own production data. If your requirement differs, send the dimensions and we will tell you which of the 155 models fits, or whether a custom route is needed.